SMOKE BAFFLES

The smoke baffles are factory installed. They
must be checked to see that they have not
become dislodged during shipping. See Fig. 14-A.
Complete the following steps to check the baffles:
1. Hold the baffle in proper position. Tilt the rear up to
clear baffle mounting brackets.
2. Push baffle up to top of combustion chamber above
all three brackets, level off, slide left and lower onto
mounting brackets.
3. Check to see that all three brackets are engaged.
4. Repeat with second baffle, making sure baffles
interlock as shown. See Fig 14-B. When properly
installed, baffles will not move more than 1/4" in any
direction.
NOTE: Failure to have baffles properly installed
will severely reduce combustion efficiency.