Draw Collar; Damper Control - Yukon Eagle Oil Furnace Owner's Manual

Eagle i - husky & eagle ii - polar oil/wood - gas/wood warm air central heating furnaces
Table of Contents

Advertisement

DRAW COLLAR (Models LWO-168 & LWG-168 ONLY)
Firmly attach the draw collar around the stainless steel
smoke pipe. Keep the field installed smoke pipe at least 2 "
away from draw collar. This will insure that smoke leaving
the furnace will not be drawn into the circulating air stream.
See Fig. 11.
NOTE: Only Models LWO-168 and LWG-168 are
equipped with a draw collar.
NOTE: If barometric damper control is installed
horizontally as illustrated, it must be at least 8
inches from furnace smoke outlet.

DAMPER CONTROL

NOTE: Refer to the wiring diagrams in the back of
manual in "Exploded Views and Parts List."
Remove control from accessory box and install as
follows:
1. Remove the four screws that hold the gasket to the
DS-103 panel.
2. Mount the DS-103 to the draft tube using screws
removed above. Make sure gasket stays in place.
See Fig. 12
3. Loosen the two screws located at slotted end of
draft tube, and remove remaining 10 screws. Make
sure gasket stays in place.
4. Mount DS-103 control and draft tube assembly to
furnace as shown. See Fig. 12
5. The electrical connections will be completed later in
the Installation Instructions.
Questions? Visit www.yukon-eagle.com or call 1-800-358-0060
Installation
CHIMNEY
Draft Tube
Assembly
16
SMOKE
PIPE
DRAW
COLLAR FILTER
DRAFT
REGULATOR
Damper Control
DOOR
FIG. 11
FIG. 12