Page 1
Carefully for Safe operation tEStEd By WARNoCK HERSEy IMPoRtANt: Installation must be made in INtERNAtIoNAL to accordance with state and local U/L 391 StANdARdS ordinances which may differ from this installation manual. Alpha American Co., 10 Industrial Blvd., Palisade, MN 56469 www.yukon-eagle.com...
Page 5
dANGER RISK of fIRE oR ExPLoSIoN do not burn garbage, gasoline, drain oil, kerosene, thinners, etc. WARNING RISK of fIRE - firing door and ash door must be tightly closed during operation. - do not operate with flue draft exceeding .03” W.C. - do not store flammable materials within marked installa- tion clearances.
dANGERS - CAUtIoN - fIRE HAZARdS (Burn wood logs or coal only) • This furnace must be installed according to the manu- facturers instructions, NFPA and local codes. • Ducts and plenums shall be constructed entirely of sheet metal. • Do not use flammable liquids to start a fire. •...
Big Jack 7. Before servicing, allow furnace to cool. Always shut off Model BJ90 and the Super Jack Model SJ125 wood burning electricity and fuel to furnace when working on it. This furnaces.
fURNACE CASING PRoPER CHIMNEyS 1. The furnace is shipped unassembled in a carton attached to The National Fire Protection Association (NFPA) requires that all the furnace. factory built chimneys be Listed and installed in accordance with conditions of the Listing in the manufacturers instructions. NFPA 2.
INStRUCtIoNS foR INStALLING fIELd R-C BARoMEtRIC dRAft CoNtRoLS CHOOSING THE LOCATION Do not attach draft control to top or bottom of flue pipe, nor in a room separated from appliance. Best location is as close to appliances as possible. INStALLAtIoN VERtICAL fLUE: Strap the collar to the flue pipe and place the draft control into the 1.
Page 11
fURNACE LoCAtEd IN CoNfINEd SPACE When the furnace is in a utility room, install two open grilles in a wall or door opening to the rest of the house. One grille will supply combustion air. Locate it near the floor. The other grille is for ven- tilation.
CoMBUStIoN AIR Make-up outside air to the furnace for proper fuel combustion must be provided by openings to the outside of the building. The open- ings of ducts supplying such make-up air shall have unobstructed areas not less than the area of the flue furnace pipe. NotE Outside air is needed to replace the air used by the burner and wood combustion process.
oPERAtIoN of yoUR NEW JACK LINE CAUtIoN Wood BURNING fURNACE Use caution when opening loading door. Avoid opening Check that your main blower and draft blower are in proper loading door rapidly. This could cause flame to flash out working order before lighting a fire. door.
MAINtENANCE 1. At tHE StARt of tHE HEAtING SEASoN... • It is advisable to have your local furnace man inspect and service your furnace for the coming heat- ing season. • The furnace, smoke pipe and chimney should be cleaned and checked for repairs. 2.
SERVICE HINtS Main blower vibrating when in use... PoSSIBLE CAUSE SoLUtIoN Loose allen screw on squirrel cage Tighten the allen screw, be sure squirrel cage did not move to one side or the other. Bad motor bearings Return blower for a replacement. Weight on squirrel cage wheel moved in shipment Try to adjust it or return blower for replacement.
Page 17
Excessive creosote build-up. A small reminder, whatever kind of fuel you burn, there is some kind of residue build-up on the furnace and chimney. Same with wood no matter how good the conditions... SoLUtIoN PoSSIBLE CAUSE If you have to use wet wood, make loads smaller and burn them The use of wet, frozen or unseasoned wood hotter.
fAULty CHIMNEy ANd/oR dRAft PRoBLEMS - CAUSES ANd CURES toP of CHIMNEy LoWER tHAN A sound chimney system is imperative, especially when burning SURRoUNdING oBJECtS REMEDY: ExtENd CHIMNEy ABoVE wood. Indoor chimneys, either masonry or type "HT" metal chim- ALL oBJECtS WItHIN 30 fEEt neys are best.
CoNtRACtoR, oR dIRECt fRoM tHE fACtoRy. PHONE: 1-800-358-0060 IMPoRtANt: FAX: 1-800-440-1994 Installation must be made in accordance with state and local E-MAIL: info@yukon-eagle.com ordinances which may differ WEBSITE: www.yukon-eagle.com from this installation manual. Alpha American Co., 10 Industrial Blvd., Palisade, MN 56469 www.yukon-eagle.com...