Download Print this page

York SPLIT-SYSTEM YHJF18 THRU 60 Technical Manual page 9

Split-system heat pumps 14.5 seer – r-410a
Hide thumbs Also See for SPLIT-SYSTEM YHJF18 THRU 60:

Advertisement

HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued)
FURNACE
MODEL
MODEL
T*(8,L)X*A12
T*(8,L)X*B12
T*(8,L)X*C16
T*(8,L)X*C20
T*9X*B12
YHJF36S41S1
T*9X*C16
T*9X*C20
Y*(8,L)C*C16
Y*(8,L)C*C20
(Y*9C/T*9V)*C16
(Y*9C/T*9V)*C20
T*(8,L)X*C16
T*(8,L)X*C20
T*9X*C16
T*9X*C20
T*9X*D20
YHJF42S41S1
Y*(8,L)C*C16
Y*(8,L)C*C20
(Y*9C/T*9V)*C16
(Y*9C/T*9V)*C20
(Y*9C/T*9V)*D20
T*(8,L)X*C16
T*(8,L)X*C20
T*9X*C16
T*9X*C20
YHJF48S41S1
T*9X*D20
Y*(8,L)C*C20
(Y*9C/T*9V)*C16
(Y*9C/T*9V)*C20
(Y*9C/T*9V)*D20
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
Johnson Controls Unitary Products
1
COIL
MODEL
MBH
FC/MC/PC37A
36.0
FC/MC/PC43B
36.0
FC/MC/PC43C
36.0
FC/MC/PC43C
36.0
FC/MC/PC43B
36.0
FC/MC/PC43C
36.0
FC/MC/PC43C
36.0
FC/MC/PC43C
36.0
FC/MC/PC43C
36.0
FC/MC/PC43C
36.0
FC/MC/PC43C
36.0
FC/MC62D
40.5
FC/MC62D
41.0
FC/MC62D
41.0
FC/MC62D
40.5
FC/MC62D
40.5
FC/MC62D
41.0
FC/MC62D
41.0
FC/MC62D
41.5
FC/MC62D
41.0
FC/MC62D
41.0
FC/MC62D
48.0
FC/MC62D
48.0
FC/MC62D
48.0
FC/MC62D
48.0
FC/MC62D
48.0
FC/MC62D
48.0
FC/MC62D
48.0
FC/MC62D
48.0
FC/MC62D
48.0
ARI HEATING
47F
COP
KW
MBH
3.80
2.78
24.6
3.80
2.78
24.6
3.78
2.79
24.0
3.88
2.72
24.4
3.80
2.78
24.6
3.82
2.76
24.4
3.74
2.82
24.2
3.72
2.84
24.4
3.74
2.82
24.2
3.76
2.81
24.6
3.70
2.85
24.4
4.06
2.92
26.0
4.08
2.94
26.2
3.98
3.02
26.2
4.02
2.95
26.2
4.02
2.95
26.0
3.96
3.03
26.4
4.00
3.00
26.2
3.86
3.15
26.6
3.90
3.08
26.4
3.94
3.05
26.4
3.78
3.72
32.0
3.80
3.70
31.8
3.76
3.74
32.0
3.80
3.70
32.0
3.76
3.74
32.0
3.76
3.74
32.0
3.72
3.78
32.2
3.68
3.82
32.4
3.72
3.78
32.2
510667-YTG-B-0509
2
17F
HSPF
COP
KW
STD
2.54
2.84
8.50
2.54
2.84
8.50
2.56
2.75
9.00
2.60
2.75
9.00
2.54
2.84
8.50
2.56
2.79
8.50
2.52
2.81
8.50
2.50
2.86
8.50
2.52
2.81
8.50
2.52
2.86
8.50
2.50
2.86
8.50
2.78
2.74
9.00
2.78
2.76
9.00
2.72
2.82
9.00
2.74
2.80
9.00
2.76
2.76
9.00
2.70
2.86
9.00
2.74
2.80
9.00
2.64
2.95
9.00
2.68
2.89
9.00
2.70
2.86
9.00
2.56
3.66
9.00
2.58
3.61
9.00
2.56
3.66
9.00
2.58
3.63
9.00
2.56
3.66
9.00
2.56
3.66
9.00
2.54
3.71
9.00
2.50
3.80
9.00
2.52
3.74
9.00
9

Hide quick links:

Advertisement

loading