510667-YTG-B-0509
HEATING CAPACITY - With High Efficiency Motor Furnaces
UNIT
VARIABLE SPEED
FURNACE MODEL
MODEL
T*(8,L)X*C20
T*9X*C20
T*9X*D20
YHJF60S41S1
Y*(8,L)C*C20
(Y*9C/T*9V)*C20
(Y*9C/T*9V)*D20
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
ACCESSORIES
Refer to Price Manual for specific model numbers.
Start Assist Kit - Provides starting torque for low voltage appli-
cations.
Blower Time Delay - Available to increase efficiency when
installed. Installs on indoor section and maintains blower for
approximately one minute after cooling thermostat has been
satisfied.
Low Temperature Cutout (2LT06700224) - Prevents heat
pump operation below -1°F ambient temperature.
10
COIL
1
MODEL
STAGE
14.5 SEER HP WITH VARIABLE SPEED FURNACES
1
FC/MC62D
2
2
1
FC/MC62D
2
2
1
FC/MC62D
2
2
1
FC/MC62D
2
2
1
FC/MC62D
2
2
1
FC/MC62D
2
2
HEATING
NET MBH
RATED
CFM
47 OD
3
835
42.0
1665
57.0
835
56.5
1220
43.5
1595
57.0
1220
55.6
1240
43.5
1645
57.0
1240
55.6
1015
42.5
1615
57.0
1015
55.6
1040
43.0
1655
57.0
1040
54.9
1085
43.0
1630
57.0
1085
55.6
Thermal Expansion Valve Kit - 1TVM4 Series TXV kit used
when required.
Outdoor Thermostat (2TD06700124) - Provides additional
staging of supplemental electric heat.
Thermostats - Compatible thermostat controls are available
through accessory sourcing. For optimum performance and
installation, refer to the UPGNET "Low Voltage Wiring Diagram"
document to select and apply controls.
2
HSPF
COP @ 47
17 OD
39.5
9.00
38.5
8.85
40.0
9.00
39.0
8.60
40.0
9.00
39.0
8.65
40.0
9.00
39.0
8.75
40.5
9.00
39.0
8.70
40.0
9.00
39.0
8.65
Johnson Controls Unitary Products
2.98
3.64
2.62
3.38
3.58
3.08
3.42
3.60
3.10
3.20
3.58
2.86
3.20
3.54
2.88
3.26
3.54
2.94