USE AND MAINTENANCE MANUAL
CHAPTER 2

LIMITATIONS

GARDEN PUMPS PENTAIR FLOTEC are suitable to pump clean water from wells, tanks, etc.; to irrigate meadows and
flowerbeds; to fill or drain collection tanks or basins; and to wash terraces or small paths.
WARNING
The pump cannot be used for sea water and inflammable, corrosive, explosive or dangerous liquids.
TECHNICAL DATA
Mains voltage / Frequency
Absorbed power
Type of protection / Insulation class
Suction fitting
Delivery fitting
Maximum flow rate*
Maximum head*
Maximum suction height including load
losses
Power cable
Weight
Maximum dimension of pumped solid
particles
Maximum admitted working pressure
Minimum ambient temperature
Maximum ambient temperature
Maximum temperature of the pumped fluid
in continuous mode
Maximum number of starts per hour,
uniformly distributed
Sound power level (Lwa)**
Sound pressure level (Lpa)
8
GARDENJET 1500
230 V ~ 50 Hz
1100 Watt
IP X4
33,25 mm (1"F)
33,25 mm (1"F)
4.800 l/h
50 m
7 m
1,5 m H07RN-F
15,8 Kg
3 mm
6 bar
5° C
40° C
35° C
40
85 dB
73,2
GJ INOX 1000
230 V ~ 50 Hz
800 Watt
IP X4
33,25 mm (1"F)
33,25 mm (1"F)
3.300 l/h
46 m
7 m
1,5 m H07RN-F
9,2 Kg
3 mm
6 bar
5° C
40° C
35° C
40
81 dB
72,8
GARDENJET INOX 1600
230 V ~ 50 Hz
1200 Watt
IP X4
33,25 mm (1"F)
33,25 mm (1"F)
4.300 l/h
50 m
7 m
1,5 m H07RN-F
9,2 Kg
3 mm
6 bar
5° C
40° C
35° C
40
82 dB
70,1