York YZB018 THRU 060 Technical Manual page 19

Split-system heat pumps 13 seer – r-410a
Hide thumbs Also See for YZB018 THRU 060:
Table of Contents

Advertisement

HEATING CAPACITY - YZB03611With Variable Speed Furnaces (Continued)
VARIABLE
SPEED
FURNACE
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
Y*(8,L)C*B12
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*B12
Y*9C*C16
Y*9C*C20
Y*(8,L)C*A12
Y*(8,L)C*B12
Y*9C*B12
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
Y*(8,L)C*C16
Y*(8,L)C*C20
Y*9C*C16
Y*9C*C20
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*A12
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*A12
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*C16
G*9V*C20
G*9V*C16
G*9V*C20
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*A12
G*9V*B12
G*9V*C16
G*9V*C20
G*9V*C16
G*9V*C20
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
Johnson Controls Unitary Products
1
COIL
MODEL
MBH
FC/MC/PC48C
35.4
FC/MC/PC48C
35.6
FC/MC/PC48C
36.0
HC42
35.4
HC42
35.4
HC42
35.6
HC42
35.4
HD48
34.8
HD48
34.6
HD48
34.6
HD48
35.0
HD48
34.8
HD48
35.2
UC36A
35.4
UC36B
35.2
UC36B
35.2
UC36C
35.2
UC36C
35.0
UC36C
35.2
UC36C
35.6
UC48C
35.6
UC48C
35.6
UC48C
35.8
UC48C
36.2
FC/MC/PC35B
35.4
FC/MC/PC35C
35.4
FC/MC/PC35C
35.8
FC/MC/PC36A
35.6
FC/MC/PC36B
35.4
FC/MC/PC36C
35.2
FC/MC/PC36C
35.6
FC/MC/PC37A
35.6
FC/MC/PC43B
35.8
FC/MC/PC43C
35.6
FC/MC/PC43C
35.4
FC/MC/PC48C
35.6
FC/MC/PC48C
36.0
HC42
35.6
HC42
35.4
HD48
35.0
HD48
34.8
HD48
35.2
UC36A
35.6
UC36B
35.2
UC36C
35.2
UC36C
35.6
UC48C
35.8
UC48C
36.2
ARI HEATING
47°F
COP
KW
MBH
3.58
2.90
23.8
3.52
2.96
24.0
3.54
2.98
24.2
3.50
2.96
23.8
3.54
2.93
23.8
3.46
3.02
24.0
3.50
2.96
24.0
3.10
3.29
23.8
3.16
3.21
23.4
3.18
3.19
23.4
3.10
3.31
23.8
3.14
3.25
23.6
3.20
3.22
24.2
3.24
3.20
24.8
3.26
3.16
24.6
3.28
3.15
24.6
3.34
3.09
23.8
3.36
3.05
23.8
3.36
3.07
23.8
3.34
3.12
23.8
3.66
2.85
24.0
3.68
2.84
23.8
3.62
2.90
24.0
3.64
2.91
24.4
3.30
3.14
24.0
3.38
3.07
24.4
3.38
3.10
23.8
3.28
3.18
24.2
3.34
3.11
24.4
3.42
3.02
24.4
3.42
3.05
23.6
3.32
3.14
24.6
3.42
3.07
24.2
3.46
3.02
24.0
3.50
2.96
24.0
3.52
2.96
24.0
3.54
2.98
24.2
3.46
3.02
24.0
3.50
2.96
24.0
3.10
3.31
23.8
3.14
3.25
23.6
3.20
3.22
24.2
3.22
3.24
24.8
3.28
3.15
24.6
3.36
3.07
23.8
3.34
3.12
23.8
3.62
2.90
24.0
3.64
2.91
24.4
271457-YTG-B-0908
2
17°F
HSPF
COP
KW
2.46
2.84
2.42
2.91
2.42
2.93
2.42
2.88
2.44
2.86
2.38
2.96
2.42
2.91
2.10
3.32
2.14
3.20
2.14
3.20
2.10
3.32
2.12
3.26
2.18
3.25
2.24
3.24
2.26
3.19
2.28
3.16
2.32
3.01
2.32
3.01
2.32
3.01
2.26
3.09
2.52
2.79
2.54
2.75
2.50
2.81
2.48
2.88
2.30
3.06
2.36
3.03
2.30
3.03
2.30
3.08
2.36
3.03
2.40
2.98
2.32
2.98
2.34
3.08
2.36
3.01
2.38
2.96
2.42
2.91
2.42
2.91
2.42
2.93
2.38
2.96
2.42
2.91
2.10
3.32
2.12
3.26
2.18
3.25
2.24
3.24
2.28
3.16
2.32
3.01
2.26
3.09
2.50
2.81
2.48
2.88
STD
8.20
8.20
8.20
8.20
8.20
8.10
8.20
7.90
8.00
8.00
7.90
7.90
7.90
8.00
8.00
8.00
8.10
8.10
8.10
8.00
8.30
8.30
8.20
8.20
8.00
8.10
8.10
8.00
8.00
8.10
8.10
8.00
8.10
8.10
8.20
8.20
8.20
8.10
8.20
7.90
7.90
7.90
7.90
8.00
8.10
8.00
8.20
8.20
19