Geothermal heat pumps single and dual capacity (78 pages)
Summary of Contents for York YZB018
Page 1
1.5 TO 5 TONS YORK HEAT PUMPS CONDENSING UNITS YZB 13 SEER R-410a Single Phase have the following available benefits and options Please, specify the following: High/Low Pressure switch, Internal Protections Factory Installed Filter Drier Isolated Compressor Compartment Low Sound Operation with Low RPM Fans...
Page 2
Visit us on the web at www.york.com Certified in accordance with the Unitary Small Equipment certifi- cation program, which is based on ARI Standard 210/240.
Page 3
246726-YTG-D-0507 http://www.rezine.net Physical and Electrical Data MODEL YZB1811 YZB02411 YZB03011 YZB03611 YZB04211 YZB04811 YZB06011 Unit Supply Voltage 208/230 – 1 – 60 187 to 252 Normal Voltage Range Minimum Circuit Ampacity 14.2 18.8 22.0 25.6 32.1 35.3 43.7 Max. Overcurrent Device Amps Min.
Page 4
http://www.rezine.net HEATING PERFORMANCE - With Air Handler AIR HANDLER COOLING RATED CFM NET MBH TOTAL SENS. UNIT MODEL MODEL SEER 1 PH HP WITH AV / SV - VARIABLE SPEED YZB01811 AV24 11.5 YZB02411 AV24 23.4 17.1 11.5 YZB03011 AV36 1000 21.2 11.5...
Page 5
246726-YTG-D-0507 http://www.rezine.net ACCESSORIES* SOUND POWER RATINGS* Hard Start Kit (024-31994-000, 024-31995-000) - Provides (dBA) UNIT MODEL increased starting torque for areas with low voltage. Cooling Heating TXV Kits - 1TV09 series thermal expansion valves precisely meter refrigerant for optimum performance. Compressor Discharge Temperature...
Page 6
246726-YTG-D-0507 http://www.rezine.net COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. YZB01811 INDOOR COIL MODEL NO. FC/MC/PC/UC18 IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 14.4 17.2 16.4 18.9 21.3 16.8 19.1 18.1 20.7 22.2 19.2 20.9 19.8 22.6 23.1 S.C.
Page 7
246726-YTG-D-0507 http://www.rezine.net COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YZB02411 INDOOR COIL MODEL NO. AHP24 ID CFM 1000 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 21.7 24.5 23.6 27.4 29.9 24.0 25.4 24.8 28.4 30.8 26.4 26.3 26.0 29.5...
Page 8
246726-YTG-D-0507 http://www.rezine.net COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YZB03011 INDOOR COIL MODEL NO. FC/MC/PC/UC36 ID CFM 1000 1200 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 27.1 29.1 29.2 33.5 37.3 29.0 30.7 30.7 34.8 38.8 31.0 32.2 32.2...
Page 9
246726-YTG-D-0507 http://www.rezine.net COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YZB03611 INDOOR COIL MODEL NO. FC/MC/PC/UC36 ID CFM 1000 1200 1400 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 33.4 35.6 36.5 41.1 44.1 35.4 36.5 37.1 41.6 44.5 37.4 37.5...
Page 10
246726-YTG-D-0507 http://www.rezine.net COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YZB04211 INDOOR COIL MODEL NO. FC/MC/PC/UC48 ID CFM 1200 1400 1600 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 41.7 43.4 41.3 47.3 50.7 44.2 44.8 42.6 48.5 50.4 46.8 46.3...
Page 11
246726-YTG-D-0507 http://www.rezine.net COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YZB04811 INDOOR COIL MODEL NO. FC/MC/PC/UC60 ID CFM 1400 1600 1800 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 49.5 49.2 48.3 52.5 56.2 51.1 49.8 48.8 53.3 56.5 52.7 50.5...
Page 12
246726-YTG-D-0507 http://www.rezine.net COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YZB06011 INDOOR COIL MODEL NO. FC/MC/PC/UC60 ID CFM 1600 1800 2000 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 56.1 58.8 57.7 63.9 68.4 57.3 59.7 59.3 65.2 68.0 58.6 60.5...
Page 13
246726-YTG-D-0507 http://www.rezine.net HEATING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YZB01811 INDOOR COIL MODEL NO. FC/MC/PC/UC18 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 22.9 23.7 24.4 21.5 22.3 23.1 20.2 21.0 21.8 20.9...
Page 14
246726-YTG-D-0507 http://www.rezine.net HEATING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YZB02411 INDOOR COIL MODEL NO. AHP24 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1000 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 29.0 30.7 32.5 28.2 29.7 31.2 27.5 28.7 29.8...
Page 15
246726-YTG-D-0507 http://www.rezine.net HEATING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YZB03011 INDOOR COIL MODEL NO. FC/MC/PC/UC36 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1000 1200 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 34.3 35.3 36.3 33.3 34.3 35.3 32.3 33.3...
Page 16
246726-YTG-D-0507 http://www.rezine.net HEATING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YZB03611 INDOOR COIL MODEL NO. FC/MC/PC/UC36 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1000 1200 1400 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 44.8 45.7 46.5 42.6 43.6 44.5 40.5...
Page 17
246726-YTG-D-0507 http://www.rezine.net HEATING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YZB04211 INDOOR COIL MODEL NO. FC/MC/PC/UC48 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1200 1400 1600 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 47.3 48.3 49.3 46.4 47.5 48.6 45.6...
Page 18
246726-YTG-D-0507 http://www.rezine.net HEATING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YZB04811 INDOOR COIL MODEL NO. FC/MC/PC/UC60 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1400 1600 1800 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 59.1 59.6 60.2 61.4 61.9 62.4 63.7...
Page 19
246726-YTG-D-0507 http://www.rezine.net HEATING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YZB06011 INDOOR COIL MODEL NO. FC/MC/PC/UC60 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1600 1800 2000 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 71.3 70.8 70.3 68.9 69.1 69.2 66.6...
Page 27
http://www.rezine.net COMMERCIAL ZONING PACKAGE The Facility Explorer Commercial Zoning Package is a complete, turnkey control system used to improve occupant comfort in a building (or section of a building) that is conditioned with a packaged rooftop HVAC unit. It accomplishes this by varying the amount of conditioned air delivered to individual zones and by intelligently cycling the rooftop unit’s heating and cooling stages to best satisfy all the zone demands.
Page 28
http://www.rezine.net COMMERCIAL ZONING PACKAGE Easy Installation • Bypass Damper and Actuator Assembly Several pieces of the Facility Explorer Commercial Zoning Package can be ordered pre-assembled from • A round or rectangular bypass damper is combined the factory to simplify installation: with an M910xHGA non-spring return actuator •...
Page 30
http://www.rezine.net TSS – Single Duct Variable Air Volume Terminal • An integrated VAV box with direct digital controls TSS Terminals provide Variable Air Volume (VAV) control eliminates the coordination and difficulties beyond the typical single duct box. They are specifically associated with factory mounting designed for precise air delivery throughout the entire operating range, regardless of the installed inlet conditions.
Page 31
TSS – Single Duct Variable Air Volume Terminal http://www.rezine.net Standard Features Optional Features Construction Construction • ARI 880 certified and labeled • 20-gauge galvanized steel construction • 22-gauge galvanized steel casing and valve • 3/4” or 1” fiberglass insulation • G90 galvanized steel •...
Page 32
http://www.rezine.net TSL – Single Duct Low Height Variable Air Volume Terminal TSL Terminals provide variable air volume (VAV) control • An integrated VAV box with direct digital controls beyond the typical single duct box. They are specifically eliminates the coordination and difficulties designed for precise air delivery throughout the entire associated with factory mounting operating range and are only 10”...
Page 33
TSL – Single Duct Low Height Variable Air Volume Terminal http://www.rezine.net Standard Features • Secondary high limit • Airflow switch Construction • Single-point power connection • ARI 880 certified and labeled • Hinged electrical enclosure door • 20-gauge, galvanized steel casing and valve •...
Page 34
http://www.rezine.net Single Duct Variable Air Volume Terminal (Model TSS) Dimensions Bypass Unit Size Weight W x H x L 10” x 10" x 11" 6 1/2“ 5 7/8” 8 3/4” 8 3/4” 12” x 10” x 11" 6 1/2“ 7 7/8” 10 3/4”...
Page 37
http://www.rezine.net Model SE Series ® UVC Emitters ™ UVC for HVAC needed to maintain microbial control. The UVC Emitter, by contrast, has a 12-month service life – and even after a full Single-Ended, Very High year, it has 2-1/2 times greater output than competitive devices Output Germicidal Light deliver on Day 1! As a result, only Steril-Aire can ensure the germicidal performance you need, with no return of microbial...
Page 38
http://www.rezine.net Model SE Specifications T T h h e e U U V V C C E E m m i i t t t t e e r r T T M M and fixture shall be factory assembled and incorporated into one integral assembly that maximizes serviceability.
Need help?
Do you have a question about the YZB018 and is the answer not in the manual?
Questions and answers