Traps Reference
Notification type
coldStart
warmStart
linkDown
linkUp
authenticationFai
lure
Comments? infodev@avaya.com
Objects
A coldStart trap signifies that the
SNMPv2 entity, acting in an
agent role, is reinitializing itself
and that its configuration may
have been altered.
A warmStart trap signifies that
the SNMPv2 entity, acting in an
agent role, is reinitializing itself
such that its configuration is
unaltered.
A linkDown trap signifies that
the sending protocol entity
recognizes a failure in one of the
communication links
represented in the agent's
configuration. TRAP-TYPE
ENTERPRISE snmp
A linkUp trap signifies that the
sending protocol entity
recognizes that one of the
communication links
represented in the agent's
configuration has come up.
TRAP-TYPE ENTERPRISE
snmp