Do you have a question about the AutoPulse Z-20 and is the answer not in the manual?
Questions and answers
MATHAI JOHNSON
March 8, 2025
HOW CAN CLEAR THE NAC POWWR SUPPLY CITY TROUBLE
1 comments:
Mr. Anderson
March 8, 2025
To clear the NAC power supply trouble on a Tyco AutoPulse Z-20, follow these steps:
1. Identify the Trouble Condition: On the Trouble in System screen, locate the NAC power supply trouble message. 2. Acknowledge the Trouble: Tap the "Press to acknowledge" button to confirm the issue. 3. Check for NAC Miswiring: The trouble message indicates a potential NAC miswire. Inspect the wiring connections for proper installation. 4. Verify Power Supply: Ensure the NAC power source is functioning correctly and providing the necessary voltage. 5. Correct Any Wiring Errors: If a miswire is found, correct the wiring according to the installation manual. 6. Reset the System: After addressing the issue, reset the panel to clear the trouble condition.
If the trouble persists, further troubleshooting or technical support may be required.
This answer is automatically generated
MATHAI JOHNSON
March 8, 2025
HOW CAN CLEAR THE NAC POWER SUPPLY HARDWIRE CONFIGURATION MIS MATCH
The 4606-9202AR is a Color Touchscreen LCD Annunciator for the AUTOPULSE Z-20. It provides remote annunciation of the AUTOPULSE Z-20 status. Access to Annunciator switch functions can be enabled or locked using the keyswitch. A maximum of six color touchscreen annunciators can be installed on a AUTOPULSE Z-20 panel. Refer to the Programmers’...
Alarm Silenced LED Supervisory LED Trouble LED Figure 2. Color Touchscreen LCD Annunciator User Interface Table 1. The AUTOPULSE Z-20 User Interface is made-up of the following components: Touchscreen Used as the panel’s input/output interface. Piezo Emits tones during Alarm, Trouble, Pri2 and Supervisory conditions.
AUTOPULSE Z-20 Agent Releasing Panel Operator’s Manual (579-1165AR) Alarm Conditions An alarm condition occurs when an initiating device (such as a manual pull station, smoke Alarm Conditions detector, etc.) activates. The panel indicates the presence of the alarm condition by: Overview: •...
Page 6
AUTOPULSE Z-20 Agent Releasing Panel Operator’s Manual (579-1165AR) Alarm Conditions, Continued Processing Alarms: There are three actions that may be taken when an alarm condition occurs: 1. Acknowledge an Alarm 2. Silence the Alarm 3. Reset the System Each step is explained in detail in the rest of this section.
Page 7
AUTOPULSE Z-20 Agent Releasing Panel Operator’s Manual (579-1165AR) Alarm Conditions, Continued Silence the Alarm: Silencing an alarm turns off all the audible notification appliances that are programmed to turn off when it is pressed. 1. Tap Alarm Functions. Date Fire Alarm in System...
Page 8
AUTOPULSE Z-20 Agent Releasing Panel Operator’s Manual (579-1165AR) Alarm Conditions, Continued Reset the System: Resetting the system allows it to return to a normal state after alarm activation. IMPORTANT: Reset the system only after the source of the alarm is determined and dealt with.
Page 9
AUTOPULSE Z-20 Agent Releasing Panel Operator’s Manual (579-1165AR) Alarm Conditions, Continued Viewing the Alarm Condition Each alarm condition contains detailed information on the point (or points) that have Details: triggered it. To access that info: 1. Tap a desired alarm condition from the Fire Alarm in System screen. The alarm condition can either be a point or a zone containing a variety of points.
A Trouble condition indicates the presence of a circuit break, or a ground, within a system point, or somewhere between the AUTOPULSE Z-20 and one of its points. It can also be used to indicate a failure in the system that requires attention.
Page 11
AUTOPULSE Z-20 Agent Releasing Panel Operator’s Manual (579-1165AR) Supervisory and Trouble Conditions, Continued Processing Supervisory and When a Supervisory or a Trouble event occurs, it needs to be acknowledged and the Trouble Conditions: cause of the event resolved for the system to return to normal. Two types of acknowledging modes can be configured on the panel.
Page 12
AUTOPULSE Z-20 Agent Releasing Panel Operator’s Manual (579-1165AR) Supervisory and Trouble Conditions, Continued Viewing the Supervisory and Each Supervisory or Trouble condition contains detailed information on the point, or Trouble Conditions Details: points, that have triggered it. To access that info, complete the following steps (Trouble screen is shown as an example): 1.
AUTOPULSE Z-20 Agent Releasing Panel Operator’s Manual (579-1165AR) Main Menu Main Menu The Main Menu screen displays the functions available at the panel Overview: To access these functions: • Tap anywhere on the touchscreen to remove the screensaver image. • Tap Menu on the user interface if the user interface is in use.
3. The AUTOPULSE Panel Programmer can be used to modify default user access levels for each function, or set user access level passcodes. Refer to document 579-1167AR: AUTOPULSE Z-20 Agent Releasing Panel Programmer’s Manual for more details. The following values are the default passcodes for each level:...
Page 15
AUTOPULSE Z-20 Agent Releasing Panel Operator’s Manual (579-1165AR) User Access Level, Continued Main Menu Panel Setup Diagnostics Alarm Log System Info Report Menu Clear Install Mode AlarmLog TrueAlarm CO Earth Fault Latch Card Swap Config HW Reset Revisions IViewMod TroubleLog...
AUTOPULSE Z-20 Agent Releasing Panel Operator’s Manual (579-1165AR) System Info System Info Use the System Info function to obtain detailed information regarding the panel and its Overview: components. Tap a menu icon to access that option’s main screen. Refer to Figure 6 for access levels required to use each option inside the System Info screen.
Page 17
Remote Annunciator. BOOTLOADER REV: 1.01.00.03 KERNEL REV: 1.01.00.10 FILESYSTEM REV: 1.01.01.15 PANELUI: 1.01.02.16 IP Info: Tap IP Info to see the IP and the MAC address of the AUTOPULSE Z-20 Date IP Info Time panel. IP ADDRESS: 192.168.1.150 HARDWARE ADDRESS:...
AUTOPULSE Z-20 Agent Releasing Panel Operator’s Manual (579-1165AR) Panel Setup Panel Setup Overview: Use the Panel Setup function to modify the configuration of the basic panel components. Tap on a menu icon to access that option’s main screen. Refer to Figure 6 for access levels required to use each option inside the Panel Setup screen.
Page 19
Panel Setup, Continued Mass Storage: Tap Mass Storage to access the functions listed below. The USB key Mass Storage must be inserted in the USB Port slot of the AUTOPULSE Z-20 CPU Card for the Mass Storage button to work. System Save...
AUTOPULSE Z-20 Agent Releasing Panel Operator’s Manual (579-1165AR) Alarm Log Alarm Log Overview: The Alarm Log screen contains a list of alarms that the panel has received. Refer to Figure 6 for access levels required for each option inside the Alarm Log screen.
AUTOPULSE Z-20 Agent Releasing Panel Operator’s Manual (579-1165AR) Trouble Log Trouble Log Overview: The Trouble Log screen contains a list of Troubles that the panel has received. Refer to Figure 6 for access levels required for each option inside the Trouble Log screen.
AUTOPULSE Z-20 Agent Releasing Panel Operator’s Manual (579-1165AR) Search Search Overview: Use the Search screen to search for configured points under panel control. Refer to Figure 6 for access levels required for each option inside the Search screen. Screen Buttons:...
AUTOPULSE Z-20 Agent Releasing Panel Operator’s Manual (579-1165AR) Diagnostics Diagnostics Overview: Use the Diagnostics function to run tests on the panel and the devices. Refer to Figure 6 for access levels required for each option inside the Diagnostics screen. Screen Buttons:...
Page 24
AUTOPULSE Z-20 Agent Releasing Panel Operator’s Manual (579-1165AR) Diagnostics, Continued Piezo Silence: Tap Piezo Silence to access the Piezo Silence Menu screen, where Piezo Silence Menu the On or Off buttons can be used to control the piezos at the panel USER and turn the Remote Annunciator’s piezo on or off.
Page 25
AUTOPULSE Z-20 Agent Releasing Panel Operator’s Manual (579-1165AR) Diagnostics, Continued Earth Fault Latch: Tap Earth Fault Latch to access the Earth Latch Menu screen, Date Earth Latch Menu Time which can be used to latch intermittent earth fault troubles to the USER panel.
Page 26
AUTOPULSE Z-20 Agent Releasing Panel Operator’s Manual (579-1165AR) Diagnostics, Continued Install Mode: Install Mode is a feature that minimizes the number of Troubles that occur when the system is being installed or is undergoing Date Install Mode Menu Time extensive service, by placing points and cards that can cause...
AUTOPULSE Z-20 Agent Releasing Panel Operator’s Manual (579-1165AR) Report Menu Tap Report Menu to access the Report Menu screen, where various types of reports Report Menu Overview: on the system points can be generated. To generate a report: 1. Tap Report Menu from the Main Menu screen to open the Report Menu screen (Figure 13).
Page 28
AUTOPULSE Z-20 Agent Releasing Panel Operator’s Manual (579-1165AR) Report Menu, Continued TrueAlarm Service: Tap TrueAlarm Service to generate a report which contains the following information: • Device Number • Custom Label • Alarm Level (sensitivity level of the device) • Average Value •...
Index, Continued Main Menu ..................................13 Mass Storage .................................. 20 NACTest ..................................26 New Search ..................................23 NoSwap ................................... 25 Panel Serial Number ............................... 17 Panel Setup ..................................18 Piezo ....................................4 Piezo Silence ................................... 25 Power LED ..................................4 Priority 2 Global Acknowledge ............................
Page 31
Index, Continued Upgrade Status ................................20 Use Alternate Config Version ............................19 User Access Level ................................14 User Access Level Chart ..............................16 User Interface ..................................4 Walktest ................................... 24 Warm Start ..................................24 WeakAnswer ................................... 26...
Need help?
Do you have a question about the AutoPulse Z-20 and is the answer not in the manual?
Questions and answers
HOW CAN CLEAR THE NAC POWWR SUPPLY CITY TROUBLE
To clear the NAC power supply trouble on a Tyco AutoPulse Z-20, follow these steps:
1. Identify the Trouble Condition: On the Trouble in System screen, locate the NAC power supply trouble message.
2. Acknowledge the Trouble: Tap the "Press to acknowledge" button to confirm the issue.
3. Check for NAC Miswiring: The trouble message indicates a potential NAC miswire. Inspect the wiring connections for proper installation.
4. Verify Power Supply: Ensure the NAC power source is functioning correctly and providing the necessary voltage.
5. Correct Any Wiring Errors: If a miswire is found, correct the wiring according to the installation manual.
6. Reset the System: After addressing the issue, reset the panel to clear the trouble condition.
If the trouble persists, further troubleshooting or technical support may be required.
This answer is automatically generated
HOW CAN CLEAR THE NAC POWER SUPPLY HARDWIRE CONFIGURATION MIS MATCH