Service And Maintenance - EcoSmart G37T Installation, Operation And Maintenance Manual

Gas burner
Table of Contents

Advertisement

ENGLISH

Service and maintenance

Although the frequency of appliance servicing and maintenance will
depend on use and the type of installation, a qualified service technician
should perform an appliance check-up annually.
Storage of an appliance indoors is permissible only if the cylinder is
disconnected and removed from the appliance.
Stainless steel will rust or corrode over time if contamination or
debris is not cleaned or removed immediately. When not in use, it is
recommended that you protect your fireplace from water damage or
corrosion with a protective cover.
WARNING
Risk of injury or property damage.
Before servicing:
• Turn off utilities to appliance
• Ensure appliance is completely cooled
Maintenance and Service Tasks
Like all fire and fireplace systems, it's important to run through regular safety checks. Please take the time to familiarise yourself
(and any other users) with the safety procedures associated with using your fire pit.
Inspect
Burner Assembly
Burner Ignition and Operation
Gas Hose with Regulator
Maintenance Tasks
Remove decorative black glass charcoal and examine burner. Vacuum and wipe out as
1
needed. Use caution when cleaning these areas
2
Inspect for warping and corrosion. Repair as necessary
Check the hose connecting the LP gas cylinder to ensure it is not damaged. Replace
3
as necessary.
4
Verify air shutter area is clean
1
Verify all gas connections are tight and leak-free
Clean burner top, inspect for plugged ports, corrosion, or deterioration. Replace
2
burner if necessary.
3
Inspect for flame problems.
Verify air shutter is clear of dust and debris and is in correct position for the gas type
4
being used.
5
Inspect orifice for soot, dirt, or corrosion
6
Verify manifold and inlet pressures. Adjust regulator as required.
The gas hose with regulator supplied with appliance must be used for LP installations.
1
The replacement must be those specified by the appliance manufacturer
WARNING
Annual inspection by qualified technician recommended.
Check:
• Obstructions of combustion and ventilation air.
• Condition of burner assembly
• Burner ignition and operation
• Burner air shutter adjustment
• Gas connections and fittings
Risk of:
• Fire
• Delayed ignition or explosion
• Exposure to combustion fumes
• Odors

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G16tEsf.2.b.g37Esf.2.b.g16

Table of Contents