ELIS PLZEŇ a. s.
The threshold flow rate (Q
flow parameters. At the manufacturer's plant, Q
customer's request , the threshold flow rate can be set at any value within the range of Q
The maximum permitted error in fluid volume measurements at flow rates between Q
(excluding) is: 5% irrespective of the fluid temperature.
The maximum permitted error in fluid volume measurements at flow rates between Q
(including) is:
1% for the fluid temperature not exceeding 50°C, and
3% for the fluid temperature greater than 50°C.
Piping I.D.
Rated pressure
Measurement precision
Fluid temperature
Ambient temperature
Ambient relative humidity
Storage temperature
Visual output via
Power source
Back-up power source
Power requirement
Line fuse
Protection against electric
shock
according
standard ČSN 332000-4-
41
Protect. class; electronic
unit
Protect.
class;
sensor,
probes
Outputs
(insulated
means
of optocouplers
Optional accessories
ELIS PLZEŇ a. s., Luční 15, P. O. BOX 126, 304 26 Plzeň, Czech Republic, tel.: +420/377 517 711, fax: +420/377 517 722
Product application, installation and service manual
Ultrasonic Flow Meter SONOELIS SE 4015 and SE 4025
) is the minimum flow rate at which the meter starts to indicate and process the fluid
NEC
NEC
DN 200 ÷ DN 1200
PN 10, on request PN 16 or PN 25 for piping sizes DN 200 ÷ DN 500
± 1% for flow rate Q > Q
± 0,5% for flow rate Q > Q
0 ÷ +150°С
0 ÷ +50°С
not exceeding 80%
-10 ÷ +70°C
two-line 16-character alphanumeric LC display unit
90 ÷ 260 V, 50/60 Hz
Li battery 3 V (lifetime 5 years)
6VA
T 250mA, 250V
to
automatic disconnection from power source in the TN – S network
IP 65
IP 54 (on request IP 68)
by
impulse output, 0.1 ÷ 10,000 l/imp, impulse length 50ms
frequency output 0 ÷ 1,000Hz (corresponding to flow rates 0 ÷ Q
relay output 24VAC/ 0.1A
RS 485 line
insulated current output 0/4 ÷ 20mA (corresponding to flow rates 0 ÷ Q
mass flow rate information
flow-rate measurements in both directions, flow direction indication
extended range of fluid temperature (up to +180°C)
sensor protection class IP 68
drinking-water meter version
sensor flanges according to alternative standards (ANSI, JIS)
Table 3 SE 4015/ SE 4025 flow meter specifications
is set at a value corresponding to the flow velocity of 20mm/s. On
(see Table 2) and fluid temperature up to 50°C (SE 4015)
2
and fluid temperature up to 50°C (SE 4025)
2
Page 9 of 44