    ................Mounting possibilities ................. Abschließende Arbeiten .................... Final steps ..................Testlauf, Betrieb ................Test running, operation ................Wartung, Reparatur ................Maintenance, repair ........... Demontage, Umweltschutz, Entsorgung 14 − 15 ........Demounting environmental protection, disposal 14 − 15 AK MS 15...
  • Page 3: Introduction

    This signal word indicates important information that prevents NOTICE RSF Elektronik encoders fulfill the requirements of standard IEC 61010-1 only if the po- damage to property. wer is supplied from a secondary circuit with current limitation as per IEC 61010 3rd Ed.
  • Page 4: Technische Daten

    40 µm 1: Wählbar / Selectable = 1,0 m/s 4 × 0,1 µs × 100 Herstellungsdatum / Manufacturing date 2: Wählbar mit Schaltsignal S2 / Selectable with switch signal S2 A: Aktiv / Active K: Deaktiviert / Deactivated AK MS 15...
  • Page 5 Technische Daten / Technical data 2 2.2 ABMESSUNGEN / DIMENSIONS AK MS 15...
  • Page 6: Sicherheitshinweise

    Lay the cable from the scanning head to the control in such a way that  it does not get caught up in operation when moving along the machine travel;  it is not crushed, kinked or otherwise damaged;  it does not run directly alongside power lines. AK MS 15...
  • Page 7: Mounting Preparations

    Direction of motion of the scanning head for positive counting direction 4.3 STÖRQUELLEN / SOURCES OF INTERFERENCE  Halten Sie den Mindestabstand von Störquellen ein. Keep minimum distance from sources of interference. ≤ 30 000 mm > 100 mm > 100 mm > 200 mm Störquellen Noise sources AK MS 15...
  • Page 8 5.1 GERÄT AUSPACKEN / UNPACK ENCODER 5.2 SCHUTZHAUBE ENTFERNEN / REMOVE PROTECTION COVER Beschädigungsgefahr durch spitzes Werkzeug! HINWEIS MONTAGEANLEITUNG MOUNTING INSTRUCTIONS AK MS 15 Abtastkopf Scanning head Die Abtastplatte ist hochsensibel und kann durch Kratzer beschädigt Ausgabe 07/2018    Art.Nr. 1250630-01 ...
  • Page 9: Mounting

    Observe the detailes for tolerances and variances (see page 10). the drawing below. Only use the included gap foil. Entfernen Sie die Abstandsfolie nach Festziehen der Montageschrauben. Remove the gap foil after tightening the mounting screws.  Max. 1,2 Nm AK MS 15...
  • Page 10: Montagemöglichkeiten

    Montagemöglichkeiten / Mounting possibilities 6.1 MONTAGEMÖGLICHKEITEN AK MS 15 / MOUNTING POSSIBILITIES AK MS 15 6.2 MONTAGE AK ZU MAßVERKÖRPERUNG / MOUNTING AK TO GRADUATION CARRIER 6.2.1 MS 15 MK 6.2.2 MS 15 MD 6.2.3 MS 15 MP 6.2.4 MS 15 BK, GK Detail MP = Kundenseitige Anschlussmaße / Required mating dimensions...
  • Page 11: Abschließende Arbeiten

    Electrical short circuit! NOTICE Connect the shield with the machine ground (field mass). The linear encoder is not protected against intrusion of intense contami- nation or water.  Protect the linear encoder by applying a protective cover or similar. AK MS 15...
  • Page 12: Testlauf, Betrieb

    Evaluation of counting signals via LED not active Steckerbelegung zu PWT 101 Funktionskontrolle Referenzimpuls RI Nur bei Überfahren der Referenzmarke Pinout adapter RSF Elektronik Function-control reference impulse RI Only by passing the reference mark standard connector pin assignment Anbau prüfen, Maßverkörperung reinigen RI ist außerhalb der Toleranz...
  • Page 13: Wartung, Reparatur

    The linear encoders are not designed for self-modification or component replacement by the customer. Linear encoders from RSF Elektronik are designed for a long service life.  Never open or modify the device yourself, as this will damage the device Preventive maintenance is not required.
  • Page 14  Do not bend or deform scales or scale tapes excessively. Biegen / verformen Sie Maßstäbe bzw. Maßbänder nicht zu stark.   Comply with the safety data sheets of solvents. Beachten Sie Sicherheitsdatenblätter von Lösungsmitteln.  AK MS 15...
  • Page 15 Observe the applicable country-specific regulations.   Beachten Sie die Vorschriften des jeweiligen Landes. More detailed information on legal regulations can be obtained Genaue Informationen zu gesetzlichen Regelungen gibt from competent authorities. die zuständige Verwaltungsbehörde. AK MS 15...
  • Page 16 Ges.m.b.H. Elektronische Längen- und Winkelmessgeräte, Präzisionsteilungen Tarsdorf 93, 5121 Tarsdorf, Österreich +43 (0)6278 / 8192-0 +43 (0)6278 / 8192-58 e-mail: info@rsf.at internet: www.rsf.at Certified acc. to ISO 9001 ISO 14001 Ausgabe/Date 06/2020   Art.Nr. 1250630-01   Dok.Nr. D1250630-05-A-02  ...