Wireless indoor thermostat

Advertisement

Range of temperatures settings.
Settings
Range
item
HYst
0.1°C to 1°C
t Lo
+ 6°C to + 40°C*
t Hi
+ 6°C to + 40°C*
AL Lo
– 9°C to + 20°C
AL Hi
+ 30°C to + 70°C
* The ranges of t Lo and t Hi can´t overlap each other.
Showing the pre-set temperature
The thermostat always shows the current room temperature in the normal
mode. Briefly pressing the knob will show the temperature which has been
set for this time. The pre-set temperature flashes 3s then it shows the current
temperature again.
Replacing the batteries
When the thermostat starts to indicate the Low Batt symbol (
working completely, replace the batteries for new ones. A Low battery report
is sent to the receiver.
Note: We strongly recommend only using alkaline batteries,
type AA 1.5V.
TP-150 wireless indoor thermostat
Factory
Description
settings
0.2°C
Hysteresis
6°C
Lower limit of regulated
temperature
40°C
Upper limit of regulated
temperature
3°C
Low temperature alarm
report
60°C
High temperature alarm
report
) or stops
Use with the AC-116 receiver
When the thermostat has been enrolled to a 2-way receiver (AC-116) it can
indicate by a blinking exclamation symbol (!) on the LCD of the thermostat
that communication has been lost.
You can block the channel to which the thermostat is enrolled with a
different device (magnetic contacts in windows for instance). Blinking of the
(▲) symbol on the thermostat LCD indicates that the thermostat is blocked.
Using the AC-116 receiver you can block the control of the thermostats at 3
levels.
1 – temperature adjustment (when the LOc menu is entered it can be unlocked)
2 – entering the menu (the temperature can be changed but access to the menu is
blocked)
3 – Locked completely (control from the thermostat is completely blocked)
When control is blocked from the AC-116 receiving unit, it is indicated on
the thermostat LCD display by the key symbol (
A weekly schedule can be set for each channel and be saved wirelessly to
the thermostat. This can be done by a AC-116 receiving unit equipped with
an AC-100LCD touch screen module. The thermostat then starts working as
a thermostat with a weekly schedule. This option is not programmable directly
on the thermostat but just from the AC-116 receiving unit.
Technical specifications
Power:
Lifetime of batteries:
Regulation range:
Temperature regulation sensitivity:
Alarm when temperature drops below ALLo:
Alarm when temperature exceeds ALHi:
Communication band:
RF range:
Operational temperature:
Dimensions:
Complies with:
Can be operated according to
JABLOTRON ALARMS a.s. hereby declares that the TP-150 module is in
compliance with the essential requirements and other relevant provisions
of Directive 1999/5/EC and 2011/65/EU. The original of the conformity
assessment can be found at
section
Note: Although this product does not contain any harmful materials we
suggest you return the product to the dealer or directly to the producer
after use. For more detailed information visit www.jablotron.com.
2 / 2
).
2x AA 1.5 V alkaline batteries
adjustable: ± 0.1- 1 ˚C
868.1 MHz, JA-100 protocol
up to 100 m (open area)
-10°C to + 70°C (no condensation)
ETSI EN 300220, EN50130-4, EN55022, + EN 60950-1
www.jablotron.com
- Technical Support
typically 1 year
+6°C to +40 ˚C
-9 to +20°C
+30°C to +70°C
66 x 90 x 22 mm
ERC REC 70-03
MMC51601