Trane RAUP 250 Installation Operation & Maintenance page 21

Split system condensing units 20-55 tons
Hide thumbs Also See for RAUP 250:
Table of Contents

Advertisement

Schematic &
Termination Diagram
SCHEMATIC&TERMINATION DIAGRAM :-RAUP250
SEE UNIT NAMEPLATE
FOR LINE VOLTAGE
FUSED DISCONNECT SWITCH
L1
L2
L3
N
FUSED
DISCONNECT
SWITCH
L1
L2
L3
N
PT
A-C1
A-C2
0L1
C1
C2
COMPR. 2
COMPR. 1
STEP 1
STEP 2
3
T1
MCB
32
T2
EVF INTERLOCK
T3
30
33
220V
POWER
33
30
SUPPLY
240
0
TX1
J5
PT PT
L1 L1 L2 L2
L3 L3
31
J3
J3
J3
C1
C2
C2
34
30
30
35
FOR CCH
FOR CCH
A2
OPTION
OPTION
A1
A1
32
32
32A
32A
A-C1
A-C1
A-C2
A-C2
EVF-C / EVF-OL
EVF
EVF-C(AUX)
C5
TB
0L2
E
5T1
5T2
5T3
CF1
CF2
31
J2
INPUT
STARTER CONTROLLER
MODULE
J4
OUTPUT
240 V - CONTROL WIRING
N
E E
30
30
J3
J3
C5
C5
31
31
30
30
FOR CCH
36
30
30
OPTION
A2
32
32
C5
C5
32B
32B
32
32
18
NOTE :-
FOR RAUP250 - COMPRESSOR OVERLOAD ARE INTERNALLY PROTECTED
LEGEND
DEVICE
DESCRIPTION
DESIGNATION
LPCO
LOW PRESSURE CUT-OUT
HPCO
HIGH PRESSURE CUT-OUT
HMWT
HIGH MOTOR WINDING T-STAT
OL 1, 2
INTERNAL OVER LOAD, COMPRESSOR
EVF-OL
INTERNAL PROTECTOR, EVAPORATOR FAN
EVF-C
STARTER, EVAPORATOR FAN
A-C1, A-C2
STARTER, COMPRESSOR
EVF
EVAPORATOR FAN
S1
SYSTEM SWITCH
CF 1, 2
FAN, CONDENSOR
MCB
CIRCUIT BREAKER
C5
STARTER, CONDENSOR FAN
PT
POWER TERMINALS
TB
BLOCK, TERMINATION
SUPPLIED & INSTALLED BY CUSTOMER
FACTORY INSTALLED
TERMINATION BLOCK, CONTROL
TX1
TRANSFORMER 240V : 21V, 8V
C1, C2
COMPRESSOR
CCH
CRANKCASE HEATER
NOTES:
1
DASHED LINES INDICATE RECOMMENDED FIELD
WIRING BY OTHERS. DASHED LINE ENCLOSURES
AND/OR DASHED DEVICE OUTLINES INDICATE
COMPONENTS PROVIDED BY THE FIELD. PHAN TOM
LINE ENCLOSURES INDICATE ALTERNATE
CIRCUITRY OR AVAILABLE SALES OPTIONS.
SOLID LINE INDICATES FACTORY WIRING.
2
REMOVE JUMPER WHEN TEMPERATURE CONTROLLER
IS INSTALLED
3
REMOVE JUMPER TO INTERFACE WITH EVF
INTERLOCK
J1
HAZARDOUS VOLTAGE!
DISCONNECT ALL ELECTRIC POWER
INCLUDING REMOTE DISCONNECTS
BEFORE SERVICING.
FAILURE TO DISCONNECT POWER
J3
BEFORE SERVICING CAN CAUSE
SEVERE PERSONAL INJURY OR DEATH.
IMPORTANT
USE COPPER CONDUCTORS ONLY
TO PREVENT EQUIPMENT DAMAGE.
UNIT TERMINALS ARE NOT DESIGNED
TO ACCEPT ANY OTHER WIRING.
32
32 33
32
32
33 30
30
FOR CCH
FOR CCH
T1
T1 T2
T2
T3
T3
T4
T4
T5
T5
T6
T6
T7
T7
OPTION
OPTION
CCH1
CCH1
CCH2
CCH2
TO STARTER
TO STARTER
CONTROLLER
CONTROLLER
JUMPER
JUMPER
J2
RAUP 250
WARNING
TX1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Raup 300Raup 400Raup 500Raup 600

Table of Contents