Economizer/Motorized Damper And Rain Hood; Power Exhaust/Barometric Relief Damper And Rain Hood; Economizer And Power Exhaust Damper Set Point Adjustments And Information; Electric Heater Cfm Limitations - Coleman BB-03 Installation Manual

Single package heat pump
Table of Contents

Advertisement

035-19315-001-A-0603
TABLE 3: ELECTRIC HEATER CFM LIMITATIONS
UNIT MODEL SIZE NOMINAL
TONS
3
4
5

ECONOMIZER/MOTORIZED DAMPER AND RAIN HOOD

The instruction for the optional economizer/motorized
damper and rain hood can be found in form 035-
07364-000. Use these instructions when field assem-
bling an economizer rain hood onto a unit. The outdoor
and return air dampers, the damper actuator, the
damper linkage, the outdoor and return air divider baf-
fles, and all the control sensors are factory mounted as
part of the "Factory installed" economizer/motorized
damper options.
POWER EXHAUST/BAROMETRIC RELIEF DAMPER AND
RAIN HOOD
The instructions for the power exhaust/barometric relief
damper and rain hood can be found in form 530.18-
N1.10V.
All of the components, including the dampers, hard-
ware, and mounting instructions are shipped in a single
package external from the unit and must be field
assembled and installed.
Power exhaust is only available as a field installed
accessory.
Unitary Products Group
VOLTAGE
5
208/230-1-60
1100
208/230-3-60
1100
460-3-60
-
575-3-60
-
208/230-1-60
1300
208/230-3-60
1300
460-3-60
-
575-3-60
-
208/230-1-60
1600
208/230-3-60
1600
460-3-60
-
575-3-60
-
MINIMUM SUPPLY AIR CFM
HEATER SIZE NOMINAL KW
7
10
1100
1200
1100
1200
1100
1200
-
1200
1300
1300
1300
1300
1300
1300
-
1300
1600
1600
1600
1600
1600
1600
-
1600
ECONOMIZER AND POWER EXHAUST DAMPER
SET POINT ADJUSTMENTS AND INFORMATION
Remove the economizer access panel from the unit.
Loosen but do not remove the two panel latches.
Locate the economizer control module, where the fol-
lowing adjustments will be made.
Extreme care must be exercised in turning all
setpoint, maximum, and minimum damper
positioning adjustment screws to prevent twist-
ing them off.
Check that the damper blades move smoothly without
binding; carefully turn the Minimum Position Adjusting
screw (found on the damper control module) fully
clockwise and then set the thermostat indoor fan switch
to the on position and then off, or energize and de-
energize terminals "R" to "G".
15
20
1200
1300
1200
1300
1200
1300
1200
1300
1300
1300
1300
1300
1300
1300
1300
1400
1600
1600
1600
1600
1600
1600
1600
1600
30
-
-
-
-
-
-
-
-
1600
1600
1600
1800
15