2.4 Noise Curve

50
40
30
20
L
FTXS24SL216
FTKS24SL216
FTKS18SL216
FTXS18SL216

2.5 Cooling and Heating Data Sheet in Rated Frequency

Cooling:
Rated cooling
condition(°F) (DB/WB)
Indoor
Outdoor
95/-
80/66.9
95/-
80/66.9
Heating:
Rated heating
condition(°F) (DB/WB)
Indoor
Outdoor
70/60
19.94/19.04
70/60
19.94/19.04
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 24.6ft.
Technical Information

Indoor side noise

M
H
SH
Indoor fan motor rating speed
Pressure of gas pipe
connecting indoor
Model
and outdoor unit
P (PSIG)
FTKS18SL216/
130~142
RKS18SL216
FTKS24SL216/
130~142
RKS24SL216
Pressure of gas pipe
connecting indoor
Model
and outdoor unit
P (PSIG)
FTXS18SL216/
507~550
RXS18SL216
FTXS24SL216/
507~550
RXS24SL216

Outdoor side noise

60
58
56
54
52
50
48
46
20
30
40
Compressor frequency(Hz)
RXS24SL216
RXS18SL216
RKS18SL216
RKS24SL216
Inlet and outlet pipe
temperature of heat
exchanger
T1 (°F)
T2 (°F)
in:46.4~51.8
in:167~181.4
out:51.8~57.2
out:98.6~118.4
in:46.4~51.8
in:167~181.4
out:51.8~57.2
out:98.6~118.4
Inlet and outlet pipe
temperature of heat
exchanger
T1 (°F)
T2 (°F)
in:167~181.4
in:33.8~37.4
out:98.6~113
out:35.6~42.8
in:167~181.4
in:33.8~37.4
out:98.6~113
out:35.6~42.8
Heating
Cooling
50
60
70
80
90
100
Fan speed of
Fan speed of
indoor unit
outdoor unit
Super High
High
Super High
High
Fan speed of
Fan speed of
indoor unit
outdoor unit
Super High
High
Super High
High
Compressor
revolution
(rps)
73
75
Compressor
revolution
(rps)
75
80
9