Front Of Unit; Remove All Exterior Panels; Painted Surfaces - Carrier ThinLINE 69NT40-541 Inspection Manual

Container refrigeration units
Table of Contents

Advertisement

Front of Unit

Refer to the
Warnings and Notes
proceeding with these instructions.

Remove All Exterior Panels

1. Examine unit for traces of oil residue. Leak check the unit, includ-
ing the compressor, using an electronic leak detector. Leaks are
typically found as a dirty/oily residue on compressor joints, high
pressure switch connection, pressure transducers (if fitted), piping
connections etc. Repair as required and clean the unit using low
pressure water, including the condenser coil.
2. Rust prevention and maintenance of painted surfaces (Refer to
Figure
12).
On-going corrosion maintenance is required. If corrosion is
found on any painted surface, remove corrosion, prime, and
paint using the following standard paint specifications.
Paint
White
Blue
ThinLINE
PrimeLINE
62-10327
Figure 12 Painted Surfaces
10
section in this manual before
Part Number
P/N 36-00071-16
P/N 76-00397-01

Hide quick links: