Chassis Console Port Pinouts - Juniper Junos Space JA2500 Hardware Manual

Hide thumbs Also See for Junos Space JA2500:
Table of Contents

Advertisement

JA2500 Junos Space Appliance Hardware Guide
Related
Documentation

Chassis Console Port Pinouts

16
Table 10: Details of a DC Power Supply Module (continued)
Item
Field-Replaceable Unit type
Power supply weight
Fans
Airflow
Power Supply Module (Status)
LED
Maximum Output Power
DC Maximum Current
DC Power Module
DC Power Supply Peak inrush
Power Module Maximum
Efficiency
DC Power Electrical Safety Guidelines on page 144
Connecting DC Power to the Junos Space Appliance on page 39
Replacing the DC Power Supply Cable on a Junos Space Appliance on page 94
Replacing the DC Power Supply Module on a Junos Space Appliance on page 95
This topic applies to the following Junos Space Appliances: JA1500 and JA2500.
Table 11 on page 17
describes the details of RJ-45 chassis console port pinouts for the
JA1500 and JA2500 appliances.
Details
Cold-swappable, if the appliance has only one power supply
module
Hot-swappable, if the appliance has an additional redundant,
functioning power supply module that is plugged into a
separate power circuit
2.60 lb (1.18 kg)
One internal fan per power supply module
From the front of the chassis to the back
One Power Supply Module LED present on the power supply
faceplate:
Green indicates that the power supply module is working
properly; the module is powered on and is powering the
appliance.
Amber indicates that the power supply module is in standby
mode; the module is powered on but it is not powering the
appliance.
Off indicates that the power supply module is not powered
on or that the module is not working properly.
560 W
20 A
–45 V to –60 V
< 60 A
80Plus 560 W cDC
Copyright © 2014, Juniper Networks, Inc.