VIEWING THE SELF CHECK DIAGNOSIS HISTORY

When an error is detected, the Self Check screen records the date(s) and
the number of times the error occurred. This is helpful in confirming past
occurrences of an error, and for determining if an error is intermittent when
the customer is not sure what is causing the television to shut down. If the
screen displays a "0", no error has occurred.
1.
Take the TV out of deep Standby mode by pressing
turn on the TV.
POWER
2.
Press
to turn the TV back off.
3.
Press the following buttons on the Remote Commander within a
second of each other:
DISPLAY
Channel
* NOTE: This differs from accessing Service Adjustments Mode
(Volume +)
KDL-40HX750/46HX750/46HX751/55HX750/55HX751
POWER
5
POWER
-
Volume
SECTION 2 - TROUBLESHOOTING
StandBy LED
Blink Count
Diagnosis
Item
SELF CHECK
000 RESERVED
--------------------- --------------------- --------------------- 00
000 RESERVED
--------------------- --------------------- --------------------- 00
to
002 MAIN_POWE --------------------- --------------------- --------------------- 00
003 DC_ALERT
--------------------- --------------------- --------------------- 00
003 AUD_PROT
--------------------- --------------------- --------------------- 00
003 HDMI_EQ
--------------------- --------------------- --------------------- 00
003 TU_DEMOD
--------------------- --------------------- --------------------- 00
004 VLED
--------------------- --------------------- --------------------- 00
004 LD_ERR
--------------------- --------------------- --------------------- 00
005 HFR_ERR
--------------------- --------------------- --------------------- 00
005 TCON_ERR
120123132522 120123113645 --------------------- 02
005 P_ID-ERR
--------------------- --------------------- --------------------- 00
006 BACKLITE
--------------------- --------------------- --------------------- 00
007 TEMP_ERR
--------------------- --------------------- --------------------- 00
007 FAN_ERR
--------------------- --------------------- --------------------- 00
010 EMITTER
--------------------- --------------------- --------------------- 00
101 VPC_WDT
--------------------- --------------------- --------------------- 00
102 MEPS_WDT
--------------------- --------------------- --------------------- 00
103 HOST_WDT
--------------------- --------------------- --------------------- 00
104 STBY_WDT
--------------------- --------------------- --------------------- 00
00345 000333 06789
Total operation time by hour (MAX:65535)
Total operation time by hour (MAX:65535)
*Format of Error History = YYMMDDhhmmss example 120123132522= Jan 23, 2012 13:25:22 (1:25:22PM)
NOTE: date and time must be set for this to work
SAMPLE SELF CHECK DIAGNOSIS PAGE
Date and Time Display*
Panel operation time by hour (MAX:65535)
Panel operation time by hour (MAX:65535)
Boot count (MAX:65535)
Boot count (MAX:65535)
Error Count