Additional Items

• Getting Started Guide Part Number 78-101320-01
• Two Power Connectors
Additional Items
The following items are not shipped with the router but are required for installation:
• Screws for mounting the router on a wall.
• Wire crimper for chassis grounding.
• Wire for connecting the chassis to an earth ground.
• Ethernet cables for connecting devices to the Ethernet ports.
• Ratcheting torque flathead screwdriver that exerts up to 15 in-lb (1.69 N-m) of pressure.
• A number-2 Phillips screwdriver.

Ethernet Devices

Identify the Ethernet devices that you will connect to the router: hub, servers, and workstations or PCs. Ensure
that each device has a network interface card (NIC) for connecting to Ethernet ports.
Installing the Cisco IC3000
This section describes how to install the Cisco IC3000. This device is designed to be mounted only from a
Din Rail.
Caution: Airflow around the device must be unrestricted.
• Temperature surrounding the unit does not exceed 140°F (60°C), which is the maximum ambient
Note: When the device is installed in an industrial enclosure, the temperature within the enclosure is greater
than normal room temperature outside the enclosure.
• Cabling is away from sources of electrical noise, such as radios, power lines, and fluorescent lighting
• Contact your Cisco TAC if tighter spacings are required.
This section contains the following topics:

Installing a DIN Rail

You can use either the 7.5-mm or the 15-mm thick DIN rail for the Cisco IC3000. Secure the DIN rail to the
mounting surface approximately every 7.8 inches (200 mm) and use end-anchors appropriately.
The device ships with a spring-loaded latch on the rear panel for a mounting on a DIN rail. See
IC3000 Rear Din Mount, on page
Caution: Do not stack any equipment on the device.
Cisco IC3000 Industrial Compute Gateway Hardware Installation Guide
18
temperature of the device.
fixtures.
Installing the Cisco IC3000 Industrial Compute Gateway
19.
Figure 3:

Hide quick links: