Using the mains rectifier

➤ Secure the mains rectifier with the fastening bracket (fig. 2, page 3).
7
Using the mains rectifier
A
NOTICE!
• Do not reverse the polarity. If the poles are reversed device may
overheat and be damaged.
• Replace defective fuses with new ones of the same rating (12 A slow-
blow).
➤ Fit wire sleeves to the ends of wires which you wish to connect to the mains
rectifier.
I
NOTE
To avoid drops in voltage and therefore performance, keep the cable
route as short as possible and only disconnect it when necessary.
➤ Determine the required cross section of the cable in relation to the cable length
according to fig. 3, page 3.
Key for fig. 3, page 3
Co-ordinate axis
l
➤ Connect the battery using the B+ and B– terminals on the front plate (fig. 4,
page 4).
➤ Connect the BD35F compressor
– using the C+ and C– terminals (fig. 5 1, page 4) or
– using the socket on the front plate (fig. 5 2, page 4).
10
Meaning
Cable length
Cable cross section
EPS100
Unit
m
mm²
EN