Rs-422 [ F ] 5T836-2; Configuring For Rs-422 Dual-State (Duplex Communications) - Raveon Tech Series Manual

Table of Contents

Advertisement

3.5. RS-422
RS-422 communications uses 4-wire differential signals. The Tech Series 422 board
has the following pin configuration.
Pin #
Name
MODE
1
2
Y+
3
Z-
4
B+
A-
5
6
GND

Configuring for RS-422 Dual-State (Duplex Communications)

The Tech Series enclosure will detect auto-detect the 422 Tech Series board and set
all necessary parameters to enable RS422 communication. The Tech Series hardware
connector is identical to the RS485 version.
Raveon's RS-422 I/O circuit uses 3.3V logic to drive the lines, and the RS422 pins are
ESD protected to ±15kV and 7kV human body model. Output is tri-state (0, 1, and
Open circuit). Tri-State is used for full duplex communications.
RS-422 installations typically have a termination resistor across the Input and the
Output lines. A value of 150 ohms should work in most applications.
Connect Pin 1 (MODE) to ground to enable the Full Duplex Dual-State operation.
Tech Series RS-485 Interface
[ F ] 5T836-2
Direction
Function
I
T Mode
Out
Out+
Out
Out-
In
In
-
Ground
Level / Specification
1(or Float)
to default to tri-state simplex mode.
0(ground
) to enable full duplex, dual mode output.
Non-inverting RS-422 data OUT line
Inverting RS-422 data OUT line
In+
Non-Inverting data INPUT pin
In-
Inverting data INPUT pin
Connect to earth ground.
13
Raveon Technologies Corp.

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Tech Series and is the answer not in the manual?

This manual is also suitable for:

Tech rv-m21 seriesTech rv-m22 series

Table of Contents