F) Activating Relay - Renkforce READER6 Operating Instructions Manual

Transponder opening system (rf reader)
Table of Contents

Advertisement

Available languages

Available languages

The relay can also work in impulse operation. The switching time is 0.5 seconds.
Impulse operation thus simulates the brief pushing of a button by this.
To programme a switching time of 0.5 seconds, proceed as follows:
• Push and hold the button (8) for at least 5 seconds.
The LED (9) lights up when a button is pushed and goes out after 1 second. After another
4 seconds, the LED (9) lights up again and the programming mode is now activated.
Now release the button; the LED will continue to be lit LED.
• Keep the button (8) pushed again until the LED flashes 3x (about 5 seconds). The
programming process is ended.
This completes the setting process of the switching time (0.5 seconds) of the relay.
f) Activate Relay
If the control module recognises that a transponder is in reach at the aerial module, the
transponder number is compared to the user transponders stored. If the transponder
number is present in the memory, the relay is activated for the saved switching time.
The LED lights up at the same time for the duration of switching.
Important!
The set switching time of the relay is started when a valid user transponder is
held against the aerial module.
The switching time of the relay is extended as long as a valid user transponder
is in the reading area of the aerial module. This means that the set switching
time will only start from the time at which the transponder has left the reading
field of the aerial module.