Functional Description - Renkforce READER6 Operating Instructions Manual

Transponder opening system (rf reader)
Table of Contents

Advertisement

Available languages

Available languages

6. Functional Description

The product can activate a relay with special transponders and thus control, e.g, a
door opener.
Up to 50 transponders can be taught into the product and saved there.
If one of these transponders is recognised when recording and evaluating the transponder
data, the relay switches (NO contact, closer).
The switching time of the relay can be set (impulse operation 0.5 s or a switching time
of 1 - 15 s in steps of 1 s).
The user transponders that are to permit a switching process of the relay and thus, e.g.,
opening of a door, are taught in by master transponder in the EEPROM and saved.
The master transponder is any „normal" transponder that serves as master
transponder after actuating of a button on the PCB of the control module. A
detailed description of this process is given in chapter 10.
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

751242

Table of Contents