F8.4: Program Change ON/OFF
Normally the P-90 will respond to MIDI program
change numbers received from an external keyboard or
other MIDI device, causing the correspondingly-num-
bered voice to be selected on the corresponding channel
(the keyboard voice does not change). The P-90 will nor-
mally also send a MIDI program change number when-
ever one of its voices is selected, causing the
correspondingly-numbered voice or program to be
selected on the external MIDI device if the device is set
up to receive and respond to MIDI program change
numbers.
This function makes it possible to cancel program
change number reception and transmission so that
voices can be selected on the P-90 without affecting the
external MIDI device.
For information on program change numbers for each of the
P-90's voices, refer to page 56 in the MIDI Data Format sec-
tion.
Setting range:
ON/OFF
Normal setting: ON
F8.5: Control Change ON/OFF
Normally the P-90 will respond to MIDI control change
data received from an external MIDI device or keyboard,
causing the voice on the corresponding channel to be
affected by pedal and other "control" settings received
from the controlling device (the keyboard voice is not
affected).
The P-90 also transmits MIDI control change informa-
tion when the pedal or other appropriate controls are
operated.
This function makes it possible to cancel control change
data reception and transmission so that, for example, the
P-90's pedal and other controls can be operated without
affecting an external MIDI device.
For information on control changes that can be used with the
P-90, refer to the MIDI Data Format on page 56.
Setting range:
ON/OFF
Normal setting: ON
F8.6: MIDI Transmit Transpose
This function allows the MIDI note data transmitted by
the P-90 to be transposed up or down in semitone incre-
ments by up to plus or minus 12 semitones. The pitch of
the P-90 itself is not affected.
Setting range:
-12 – 0 – 12 (in semitones)
Normal setting: 0
F8.7: Panel/Status Transmit
This function causes all the current P-90 panel settings
(selected voice, etc.) to be transmitted via the MIDI OUT
terminal. This is particularly useful if you will be record-
ing performances to a MIDI sequence recorder, such as
the Yamaha MIDI Data Filer MDF3, which will be used
to control the P-90 on playback. By transmitting the P-90
panel settings and recording them on the MIDI sequence
recorder prior to the actual performance data, the P-90
will be automatically restored to the same settings when
the performance is played back.
Setup Data:
Data that contains a set of panel settings for the P-90.
Procedure
1. Set up the panel controls as desired.
2. Connect the P-90 to a sequencer via MIDI, and set up
the sequencer so it can receive the setup data.
3. Engage Function mode and select
4. Press the
[+/YES]
button to transmit the panel/status
data.
will appear on the LED display when the data has
been successfully transmitted.
See page 57 for a list of the "Panel Data Contents" transmitted
by this function.
Receiving the transmitted data:
1. Connect the P-90 via MIDI to the device to which the setup
data was transmitted previously.
2. Start sending the setup data from the device.
The P-90 automatically receives the setup data, which will be
reflected in the panel settings.
(For the data to be accepted, the P-90 that receives the setup
data should be the same model as the one that transmitted
the setup data to the sequencer.)
For more information on transmitting and receiving setup data
via MIDI, refer to the owner's manual for the connected MIDI
device.