    V2.7 06/2019 USER MANUAL VARILYMPH 12 PRO CONTENTS 1. ABOUT 2. SAFETY INSTRUCTIONS 3. SCOPE OF SUPPLY 4. FIELD OF APPLICATION 5. OPERATION INSTRUCTION 6. END OF THERAPY 7. CLEANING 8. SERVICE 9. TECHNICAL SPECIFICATIONS...
  • Page 2: About

    (foot, hand) areas from the heart and moves in 12 steps to the body nearest areas. The actual therapy pressure can be adjusted at the controller. The de- and inflation of the air cells in the correct order is controlled by the VARILYMPH 12 PRO automatically. The therapy activates the venous and lymphatic circulation.
  • Page 3: Field Of Application

    V2.7 06/2019 4. FIELD OF APPLICATION INDICATIONS • thromboembolic prophylaxis • venous oedema • ulcus cruris • lymphatic oedema • post-traumatic oedema • mixed forms of oedema • lipoedema • peripheral arterial occlusive disease (under strict medical supervision) • sensory disturbance caused by hemiplegia •...
  • Page 4 V2.7 06/2019 control unit front back tube connector power switch control dial display power supply tube connector with cover cap inflation time deflation time time of therapy start / stop • after switching on the device by the power switch the graphic on the display starts automatically •...
  • Page 5: End Of Therapy

    V2.7 06/2019 6. END OF THERAPY The device turns off automatically when the treatment time is up. The device changes over to standby mode. Disconnect the tubes to deflate the garments. Always wait till the garments are fully deflated before opening the zipper to get out of the garments.
  • Page 6: Service

    If there are any questions please don´t hesitate to contact the SLK GmbH. 8.1 Error messages and troubleshooting The VARILYMPH 12 PRO is programmed in a way that the function of the device is monitored by electronics during operation. The following error messages may occur Warning "Check for leakage": the electronics has determined that the selected target pressure could not be established.
  • Page 7: Technical Specifications

    700mbar to 1060mbar medical device class IIa protection class II (insulation protected device) For VARILYMPH 12 PRO a manufacturer's warranty of 2 years applies. All parts and data are in constant development and may therefore differ from the information listed.
  • Page 8 V2.7 06/2019 SLK Vertriebsgesellschaft mbH Am Herdicksbach 18 45731 Waltrop • GERMANY phone: +49(0)231 – 925360 – 0 fax: +49(0)231 – 925360 – 29 email: info@slk-gmbh.de web: www.slk-gmbh.de...