Download Print this page

Panasonic EQ-500 Series Instruction Manual page 2

Photoelectric sensor, adjustable range reflective
Hide thumbs Also See for EQ-500 Series:

Advertisement

If pressure terminals are to be used, affix the connected
pressure terminals to a terminal (M3.5 screw).
Dimensions of the suitable crimp terminals
Round type
22 or less
3.6
3.6
or more
or more
10
or less
17
7
7.5
or less
7.5
or less
or less
or less
(After crimping)
The tightening torque of the terminal screws should be
0.3 to 0.5N m.
6
I/O CIRCUIT DIAGRAMS
Multi-voltage type
Terminal No.
Power supply
Multi-voltage
24 to 240V AC 10%
circuit
or
12 to 240V DC 10%
Output relay
Relay contact
(1a)
Internal circuit
DC-voltage type
Terminal No.
D
Z
100mA max.
T
D2
r2
T
Z
r1
D1
Internal circuit
Users' circuit
Symbols...D: Reverse supply polarity protection diode
Z
, Z
: Surge absorption zener diode
D1
D2
T
: NPN output transistor
r1
T
: PNP output transistor
r2
Terminal position
7
PART DESCRIPTION
Stability indicator (Green)
Distance adjuster
OFF-delay timer switch
(2-turn)
(Note 2)
ON-delay timer switch
Adjuster indicator
(Note 2)
Operation indicator (Orange)
Operation mode switch (Note 1)
Notes: 1)
The operation mode switch of the DC-voltage type is the
DIP switch. Refer to '
8
OPERATION MODE SWITCH' for
details.
2)
Incorporated on EQ-5 T only.
8
OPERATION MODE SWITCH
Multi-voltage type (L-ON / D-ON mode only)
Operation mode switch
Description
Detection-ON mode is obtained when the
switch is turned fully clockwise.
Detection-OFF mode is obtained when the
switch is turned fully counterclockwise.
Note: Turn the operation mode switch gradually and lightly with the
attached screwdriver. If the distance adjuster is over turned or
pressed heavily, it may be damaged.
DC-voltage type
L-ON / D-ON mode
L
BGS / FGS mode
BGS
Timer mode
OFF
Not used
N.C.
9
BGS / FGS FUNCTION
(DC-voltage type only)
(Unit: mm)
This sensor incorporates BGS / FGS function. Select
Y-shaped type
either BGS or FGS function depending on the
positions of the background and sensing object.
22 or less
BGS / FGS function is set with the operation mode switch.
10
Depends on a selection of either BGS or FGS
or less
function, the output operation changes as follows.
17
7
or less
or less
Non-detectable area
(After crimping)
L-ON
BGS
D-ON
L-ON
FGS
D-ON
<BGS function>
This function is used when
the sensing object is apart
from the background.
<FGS function>
This function is used when the
sensing
background or the sensing object is
glossy, etc.
10
DISTANCE ADJUSTMENT
For DC-voltage type, be sure to set the BGS / FGS function
before distance adjustment. If the setting is done after the
distance adjustment, the sensing area is changed.
+
12 to 24V DC
Turn the distance adjuster gradually and lightly with
10%
-
the attached screwdriver. If the distance adjuster is
100mA max.
over turned or pressed heavily, it may be damaged.
Multi-voltage type, DC-voltage type BGS select
<When a sensing object moves horizontally to the sensor>
Step
Turn the distance adjuster fully counterclock-
wise to the minimum sensing range position.
(0.2m approx.)
Please an object at the required distance
from the sensor, turn the distance adjuster
gradually clockwise, and find out point
where the sensor changes to the light
received condition.
Remove the object, turn the distance adjuster
further clockwise, and find out point
the sensor changes to the light received
condition again with only the background.
When the sensor does not go to the light
received condition even if the adjuster is fully
turned clockwise, point
The optimum position to stably detect objects
is the center point between
When a sensing object is approaching / moving
away from the sensor.
Follow only steps
may change depending on the sensing object, be sure
to check the operation with the actual sensing object.
DC-voltage type FGS select
Step
Turn the distance adjuster fully clockwise to
the maximum sensing range position. (2.5m
approx., 1.0m approx. for EQ-512
In the state where the sensor detects the
background, turn the distance adjuster gradu-
ally counterclockwise, and find out point
where the sensor changes to the undetecting
condition.
Place an object at the required distance from the sensor, turn
the adjuster counterclockwise further until the sensor goes
into the undetecting condition again. Once it has entered, turn
D
the adjuster backward a little until the sensor returns to the
FGS
detecting condition. That position is designated as point
When the sensor does not go into the undetecting
Timer ON
condition even if the adjuster is fully turned
N.C.
counterclockwise, the position where the adjuster
was fully turned is regarded as the point
The optimum position to stably detect objects
is the center point between
Sensing range
Adjusted distance
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Sensing object
object
contacts
the
Sensing
object
Background
Distance
Description
adjuster
Turn fully
where
is this extreme point.
and
.
and
. Since the sensing point
Distance
Description
adjuster
Turn fully
.
.
Optimum
position
and
.
11
STABILITY INDICATOR
Since the EQ-500 series use a 2-segment photodi-
ode as its receiving element, and sensing is done
based on the difference in the incident beam angle
of the reflected beam from the sensing object, the
output and the operation indicator (orange) operate
according to the object distance.
Further, the stability indicator (green) shows the
margin to the setting distance.
Setting distance
Output
(operation indicator)
(In case of Detection-ON)
Stable
Stability indicator
operating
condition
12
TIMER FUNCTION (EQ-5 T only)
An OFF-delay timer, which is useful when the
response of the connected device is slow, etc., an
ON-delay timer, which is useful when the input
specifications of the connected device require a
signal of a fixed width, are possible with EQ-5 T.
The OFF-delay timer and the ON-delay timer can
be used at the same time.
For DC-voltage type, set the DIP switch for the
timer selecting to 'Timer ON' side.
<Time chart>
Sensing
condition
Operation
Light-received
normal operation
Light-received
T
ON-delay
Light-received
T
OFF-delay
Light-received
T
T
ON/OFF-delay
Light-interrupted
normal operation
Light-interrupted
T
ON-delay
Light-interrupted
T
OFF-delay
Light-interrupted
T
T
ON/OFF-delay
Timer period: T = 0.1 to 5s (variable)
Optimum
Note: Turn the timer switch gradually and lightly with the
position
attached screwdriver. If the distance adjuster is over
turned or pressed heavily, it may be damaged.
13
INTENDED PRODUCTS FOR
CE MARKING
The models listed under "
FICATIONS" come with CE Marking.
As for all other models, please
contact our office.
Contact for CE
Panasonic Marketing Europe GmbH Panasonic
Testing Center
Winsbergring 15, 22525 Hamburg,Germany
https://panasonic.net/id/pidsx/global
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
For sales network, please visit our website.
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
Sensing object
ON (lights up)
OFF (lights off)
Lights up
Stable operating
condition
Lights off
Unstable operating
condition
Beam-re
ceived
Beam-inter
rupted
ON
OFF
ON
OFF
ON
T
T
OFF
ON
OFF
ON
OFF
ON
T
T
OFF
ON
OFF
ON
OFF
1
SPECI-
PRINTED IN THAILAND

Advertisement

loading