videotronic IX-1000AL/IP Mounting And Operating Instructions page 10

Table of Contents

Advertisement

MANUAL:
Manual White Bal., in the submenu the values are adjusted and stored.
Proper White Balance may not be obtained with ATW under following conditions, in
Note:
these cases select AWC mode:
When the scene contains mostly high colour temperature objects, such as a blue sky.
When the scene is dim.
If your camera faces fluorescent lamp directly or is installed in the place of changing
illumination.
BACKLIGHT
When there is a strong backlight behind the object, clear images of the background
as well as the object can still be obtained by using the BACKLIGHT function. This
function has four values: Off, Low, Middle, High
AGC
The IX 1000A offers four settings:
The IX 3000A offers three settings:
Note:
If the AGC is set to Off following functions not available: DNR, SENSE UP and
DAY / NIGHT Function.
DNR
In low light conditions this functions increases the noise in the picture. There are four
values for this setting: Off, Low, Middle, High
SENSE UP
AUTO:
In the automatic mode you have to set the limit for sense up in the submenu. The
sense up function is activated automatically in case of low light.
OFF:
The function does no operate.
Note: In the manual shutter mode the sense up does not operate.
The higher the sense up, the higher the after image effects with moving objects
Off, Low, Middle, High
Off, Normal, High
-10-