Shut-Down Parameters - Brusa NLG513 Technical Data And Start-Up

Table of Contents

Advertisement

8.2.7.2

Shut-Down Parameters

Overheating!
Fire hazard!
There is a danger of the battery catching fire if the wrong parameters or limit values are entered!
Any adjustment values must be adopted from the connected battery's technical documentation or be
given clearance by the manufacturer!
Shut-down parameters function as an additional safety installation. The charger is shut down for
safety reasons anyway if one of these parameters is reached or surpassed.
1.
Battery temperature over (°C):
Charger shuts down if the battery exceeds the
given maximum temperature.
3.
Battery charge more than (Ah):
Charger shuts down if the given capacity is
charged.
(Entry 999 = never shut down)
68
WARNING
INFORMATION
2.
Battery voltage over (V):
Charger shuts down if the given maximum battery
voltage is exceeded.
4.
Charging time longer than (h):
Charger shuts down if the given charging time is
reached.
(Entry 999 = never shut down)
Technical data
and start-up
NLG5 charger

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents