Advertisement

P2500
User Manual
Version 1.0
Errors excepted; subject to change
www.colormetric.net

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P2500 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Colormetrics P2500

  • Page 1 P2500 User Manual Version 1.0 Errors excepted; subject to change www.colormetric.net...
  • Page 2: Table Of Contents

    Resistive Type Touch Panel & P-CAP MagStripe Card Reader Configuration Utility Fingerprint Reader RFID Internal VFD 6-6 Configuration Utility of I-Button Reader Installation and Testing of Smart Card Reader WiFI Pole type VFD VD1 7 BIOS/UTILITY SETUP 8 LCD SURFACE CLEANING www.colormetric.net Colormetrics P2500...
  • Page 3: Copyright

    We reserve the right to revise this document or make changes in the specifications of the product described therein at any time without notice and without obligation to notify any person of such revision or change. Colormetrics P2500 www.colormetric.net...
  • Page 4: Safety Instructions

    Dispose used batteries according to the manufacture’s instructions. Do not remove the cover, and ensure no user serviceable components are inside. Take the unit to the service center for service and repair. www.colormetric.net Colormetrics P2500...
  • Page 5: Packing List

    Pole VFD RFID (13,56 MHz, Khz) 8” pole customer display iButton 15” pole customer display Smart card reader UPS battery Addimat waiter key Fingerprint reader *Note: Nearly all modules are also available as 2-in-1 or 3-in-1 solution. Colormetrics P2500 www.colormetric.net...
  • Page 6: System View

    3. RJ11 (Cash Drawer) 10. PS2(K/B) 4. RJ45(LAN) 11. 19V DC Input 5. USB 2.0 x2 12. Parallel port (Option) USB 3.0 x2 13. Power Button 6. COM2 14. MSR/Smart Card/ i-Button/ 7. VGA Fingerprint/ RFID (Option) www.colormetric.net Colormetrics P2500...
  • Page 7: Specification

    0°C ~ 35°C Storage Temperature -20°C ~ 60°C Storage Humidity 20% ~ 80%, non-condensing Display LCD Panel Size 15-inch TFT LED LCD Resolution 1024*768 Pixels Brightness 350 cd/m2 5-wire Resistive Type / Projected Capacitive Type (optional) Touch Panel Colormetrics P2500 www.colormetric.net...
  • Page 8: Internal Layout

    2-3 Internal Layout www.colormetric.net Colormetrics P2500...
  • Page 9: Touch Panel Life Test Condition

    AA area. The measurement items must satisfy the under-mentioned items. Writing force shall be 250g and writing speed 3,000 times per hour. - Resistance state should the same 5.1 - Linearity should the same 5.2 - Insulation resistance should the same 5.3 Colormetrics P2500 www.colormetric.net...
  • Page 10: Pin Definition

    Pin NO. Pin Name Description Ground Ground Line OUT R Line out Line OUT L Line out Detect Detect 4. VFD Connector COM4 Pin NO. Pin Name Description NDSR Ground NDTR NRTS NCTS NTXD NRXD Ground +12V www.colormetric.net Colormetrics P2500...
  • Page 11 DATA 1- LVDS Output DATA1- 9. Extra USB CN6 8. Inverter CN1 Pin NO. Pin Name Description Pin NO. Pin Name Description +12V Ground - DATA + DATA BKL_CTL Back Light Brightness Ground BKL_EN Back Light Enable Ground Colormetrics P2500 www.colormetric.net...
  • Page 12: Rear I/O Interface

    Green Analogue Ground Monitor ID 3 Blue Analogue Ground 3. USB port Signal Name Wire Colour Comment Cable Power - Data White Data Transfer + Data Green Data Transfer Ground Black Cable Ground Shell Shield Drain Wire www.colormetric.net Colormetrics P2500...
  • Page 13 Not Used 6. RJ11 port (for Cash Drawer) Signal Name Direction Frame GND Drawer Kick-out drive signal 1 Output Cash Drawer Status Input +12V Signal GND 7. DC Jack Signal Name DC IN 19V Ground DC IN 19V Colormetrics P2500 www.colormetric.net...
  • Page 14: System Assembly & Disassembly

    1. Unfasten the HDD cover screw*2 2. Pull out the HDD bracket 3. Fasten the screw*4 4. Place the HDD bracket back to the module 5-2 CF-Card 1. Please notice the unnotched CFast Card . This side up. www.colormetric.net Colormetrics P2500...
  • Page 15 2. Before Installing CF Card. 3. After Installing CF Card. Colormetrics P2500 www.colormetric.net...
  • Page 16: Msr

    2. Single MSR or 3-in-1 MSR 3. Screw*2 M3x10L 4. Fasten the screw 5-4 Cable cover Assemble the cable cover from bottom and make sure the two latches are on the right position. Then fasten 2 screws (M3*5L). www.colormetric.net Colormetrics P2500...
  • Page 17: 8"/15" 2Nd Display

    * Power supply must be replaced to 120W above power adapter. (1) Remove the plastic pole cover from the stand. (3) Fasten the four screws (M4*8L) to joint the (2) Install the pole into the socket in clockwise VESA bracket and the rear cover. direction. Colormetrics P2500 www.colormetric.net...
  • Page 18 (M3*5L). (9) Reeve the cables out of the tube. (10) Mount the VESA bracket on the pole and route cables out of the tube of VESA bracket. Fasten the thumb screw to fix the VESA bracket. www.colormetric.net Colormetrics P2500...
  • Page 19 (11) Connect the DC power cable as shown in figure (1). (12) Connect the VGA cable as shown in figure (2). (13) Connect the Audio cable as shown in figure (3). (14) Put the cable cover on the hinge of VESA bracket. Colormetrics P2500 www.colormetric.net...
  • Page 20: Internal Vfd

    Wear cotton gloves, wrist strap and may not wear watches, rings, etc. Screws to lock in place and can not lost Electric screwdriver Torque to be regularly calibrated, Alternative of external COM3 (RJ45 Connector) or Internal VFD. www.colormetric.net Colormetrics P2500...
  • Page 21: Wi-Fi

    WI-Fi Module and antenna on VFD cover. 2. Assemble VFD cover and Back panel with 2 screws. Then connect Wi-Fi /MSR cable to Wi-Fi module. 2. Connect Wi-Fi /MSR cable to M/B. Alternative of WiFi or Internal VFD. Colormetrics P2500 www.colormetric.net...
  • Page 22: 8" 2Nd Display

    5-8 8” 2nd Display 1. Remove the plastic pole cover from the stand. 2. Install the pole into the socket in clockwise direction. www.colormetric.net Colormetrics P2500...
  • Page 23 3. Connect VGA cable and DC power cable 4. Fasten the four screws (M4*8L) to joint the VESA bracket and the rear cover. 5. Reeve the cables out of the tube. Colormetrics P2500 www.colormetric.net...
  • Page 24 9. Connect the DC power cable as shown in figure. To setup COM port PIN9 with 12V DC output from BIOS setup, please refer to page 12, Advanced Chipset Features / COM port PIN9 setting. www.colormetric.net Colormetrics P2500...
  • Page 25 10. Connect the VGA cable as shown. 11. Put the cable cover on the hinge of VESA bracket. Colormetrics P2500 www.colormetric.net...
  • Page 26: 2D / Ibutton With Rfid Module

    Connect the cable as shown. * Before COM port cable connection, please setup COM port PIN9 with 5V DC output from BIOS setup. Please refer to page 12, Advanced Chipset Features / COM port PIN9 setting. www.colormetric.net Colormetrics P2500...
  • Page 27: Pole Type Vfd Vd1220

    1 Take VFD panel and two VFD poles out from the package box and Install two tubes into one pole and reeve the cable from the VFD panel through the socket of stand. VFD Panel VFD Pole 2 For the foot ring assembly, please install the foot ring into the socket in clockwise direction. Colormetrics P2500 www.colormetric.net...
  • Page 28 3 Then install the pole into the foot ring. 4 Then connect RJ45 cable to POS terminal’s RJ45 port www.colormetric.net Colormetrics P2500...
  • Page 29: Device Driver Installation

    6 DEVICE DRIVER INSTALLATION 6-1 Resistive Type Touch Panel and P-CAP 1. Click “Next” 2. Click “Next” Colormetrics P2500 www.colormetric.net...
  • Page 30 3. Click “Next” 4. Select “None”, Click “Next”. 5. Click “OK” www.colormetric.net Colormetrics P2500...
  • Page 31 6. Select “Support Multi-Monitor System”, Click “Next”. 7. Click “Next”. Colormetrics P2500 www.colormetric.net...
  • Page 32 8. Click “Next”. 9 Click “Next” www.colormetric.net Colormetrics P2500...
  • Page 33 10. Select “Create a eGalaxTouch Utility shortcut on desktop”, Click “Next”. Colormetrics P2500 www.colormetric.net...
  • Page 34 11. Would you do 4 point calibration now? Click “Yes”. 12. Do 4 points aligrment to match display 13. Calibration utility www.colormetric.net Colormetrics P2500...
  • Page 35: Magstripe Card Reader Configuration Utility

    1 The utility program will detect the connected reader. If detected, all the input text boxes will be enabled. 2 If the reader has not been connected to PC yet, please connect the reader and then click Refresh to get connected. Colormetrics P2500 www.colormetric.net...
  • Page 36 3 Error Message: Indicates which track number cause the error. 4 Delimiter: Indicates the swipe result. 5 ISO: Define start and end sentinel character. 6 Decode Mode: Determines the way of outputting the three tracks data. www.colormetric.net Colormetrics P2500...
  • Page 37 4 TK3: For the prefix string, it is appended in the front of the start sentinel of track 3. For the suffix, it is appended in the end of the end sentinel of track 3. The max data length of the prefix and suffix for the TK1 can be up to 127. Colormetrics P2500 www.colormetric.net...
  • Page 38 MSR data string contains other track data, it will still not to be output. 3 Disable: If selected, the data of specified track will not be packaged in the MSR data string. No matter it is decoded or not. www.colormetric.net Colormetrics P2500...
  • Page 39 To load pre-saved settings, click Open, specify the settings file, and then click OK to load into program. Restore MSR Reader Settings To load restore settings of connected MSR reader, click Restore ES2: End sentinel for track. Colormetrics P2500 www.colormetric.net...
  • Page 40 Software folder of CD. 3 Follow the wizard to complete the installation. Launching Program Below steps guide you how to load the Utility program. 1 From Start/Programs, click MagSwipe folder 2 Click MagSwipe Configuration Utility to launch the program. www.colormetric.net Colormetrics P2500...
  • Page 41 Configuration Select Reader Interface The reader to be configured should be connected. Select the corresponding connected reader interface and click the Continue button Colormetrics P2500 www.colormetric.net...
  • Page 42 After selecting the appropriate interface for the reader, select one of the Home Menu Page buttons to proceed with the Magnetic Stripe Reader (MSR) configuration process. The „Basic Reader Settings“ group defines the basic operating parameters and data output format of the reader. www.colormetric.net Colormetrics P2500...
  • Page 43 When the reader has received the data correctly, the settings take effect immediately. Load From File The configuration data can be loaded into the configuration utility from a file that has been previously saved. Select this command, start a „File Open“ dialog, which allows selection of the file. Colormetrics P2500 www.colormetric.net...
  • Page 44 The settings take effect immediately. The default parameters affect all reader configurations settings. Close Close this dialog and return to the Home Menu Page. General Settings This group of configuration settings defines the basic operating parameters of the reader. www.colormetric.net Colormetrics P2500...
  • Page 45 (host) require an inter-character delay to simulate the effects of keystroke delays. Choosing a longer inter-character delay causes the characters to be sent at a slower rate. If the host system is not capable of receiving characters as fast as the reader Colormetrics P2500 www.colormetric.net...
  • Page 46 These can be special characters for identifying a specific track. End Sentinel The magnetic stripe End Sentinel character can be added to the end of a magnetic stripe data string. This character simulates the end of character for track1, track2 or track3. This default is ‚?‘ www.colormetric.net Colormetrics P2500...
  • Page 47 The reader can only send account Number if it is true. And if it is false, the reader sends all Track 2 data. Send Error Indication This option let reader to send out [SS]E[ES] if failed to read or missing data on a selected track.The default is off. Colormetrics P2500 www.colormetric.net...
  • Page 48 The user can input the number between 1 to 255 for the delay of output. Check Current Reader Setting After you connect the device, the current reader configuration can be displayed by selecting this button. The configuration data of the connected reader will be displayed like in the example: www.colormetric.net Colormetrics P2500...
  • Page 49 Colormetrics P2500 www.colormetric.net...
  • Page 50: Fingerprint Reader

    6-3 Fingerprint Reader Step 1 Check Fingerprint reader be detected by “Device manager” P2500 Step 2 Select SDK folder. Step 3 Run Setup.exe. www.colormetric.net Colormetrics P2500...
  • Page 51 Step 4 Click “Next”. Step 5 Select “ I accept the terms in the license agreement” and click “Next”. Colormetrics P2500 www.colormetric.net...
  • Page 52 Step 6 Click “Next”. Step 7 Click “Next”. www.colormetric.net Colormetrics P2500...
  • Page 53 Step 8 Click “Install”. Step 9 Click “Finish”. Colormetrics P2500 www.colormetric.net...
  • Page 54 Step 10 Restart system Step 11 Check Fingerprint reader in Device Manager. P2500 www.colormetric.net Colormetrics P2500...
  • Page 55 Step 12 Launch Fingerprint reader from start menu Step 13 Select “COM-ActiveX” Colormetrics P2500 www.colormetric.net...
  • Page 56 Step 14 Select “Sample” Step 15 Select ”VB6’ www.colormetric.net Colormetrics P2500...
  • Page 57 Step 16 Select “Enrollment Sample”. Step 17 Enroll the fingerprint by the “Enrollment“ Colormetrics P2500 www.colormetric.net...
  • Page 58 Step 18 Select “Fingerprint Enrollment” www.colormetric.net Colormetrics P2500...
  • Page 59 Step 19 Put your finger on fingerprint reader and follow the direction to enroller your fingerprint, it need scan your fingerprint 4 times Step 20 after enroller finish it will popup a dialog box Colormetrics P2500 www.colormetric.net...
  • Page 60: Rfid

    1.1 Check the Device Manager to verify the status of RFID reader. Computer Management -> Device Manager -> Other devices (The device will show a question mark if the installation is not done properly.) P2500 1.2 Install RFID driver file name: XP2KxVista.exe 2-1 Path:\USB Driver\ XP2KxVista.exe www.colormetric.net Colormetrics P2500...
  • Page 61 1.2.1 After clicking Next, A pop up console window appears as below. 1.2.2 Check the Device Manager to verify the status of RFID reader. Computer Management -> Device Manager -> Ports (COM & LPT) P2500 Colormetrics P2500 www.colormetric.net...
  • Page 62 1.3 install RFID utility MifareDemoSetup_PSW00020.exe 3-1 Path:\MF320\MifareDemoSetup_PSW00020.exe www.colormetric.net Colormetrics P2500...
  • Page 63 1.3.1 InstallaShield Wizard will be activated. 1.3.2 Click “Next” 1.3.3 Click “Next” Colormetrics P2500 www.colormetric.net...
  • Page 64 1.3.4 Click “Giga-TMS” & “Next” 1.3.5 Click “Next” www.colormetric.net Colormetrics P2500...
  • Page 65 1.3.6 Click “Next” 2 Run RFID demo program. Start -> All Programs -> GIGA-TMS -> Mifare Demo Colormetrics P2500 www.colormetric.net...
  • Page 66 2-1 Run “Auto Scan” Demo AP will detect the RFID reader automatically. Or select the RFID COM port www.colormetric.net Colormetrics P2500...
  • Page 67 2-2 After finishing the AutoScan, Request box will be ready for the click and Reader Version will show on the position as marked. (Reader Version: PGM-T1235 V1.0R3 (101230) Place Mifare Card to the RFID reader area. Event Dialog window gets the data from the Mifare Card Place the RFID card on the RFID reader. Colormetrics P2500 www.colormetric.net...
  • Page 68 2-3 Card type will be recognized when you click “Request”. (Your Mifare card should be placed on the RFID reader area.) 2-4 Card ID will be recognized when you click “Card ID”. www.colormetric.net Colormetrics P2500...
  • Page 69 2-5 SAK will be read when you click “Select”. 2-6 The result will show when you click “Authenticate” Colormetrics P2500 www.colormetric.net...
  • Page 70: Internal Vfd

    Katakana, Lativian, Lithuanian, Norwegian, Polish, Portuguese, Romanian, Russian, Slovene, Slovak, Spanish, Swedish Interface RS-232 (serial) Reliability Baud rate Direct connection 9600 or 19,200 bps Connection MTBF 30,000 hours Power Consumption 5 VDC EMC standards Safety FCC, CE Safety standards www.colormetric.net Colormetrics P2500...
  • Page 71 3. “Get Setting From VFD” button To get all setting from the display and It´ll refresh the “VFD_Setup.exe” utility 4. “Character Type” / “Comand Mode” / “BaudRate Selcet” / “Passthru Mode” Please refer to Chapter 4-5 user manual Colormetrics P2500 www.colormetric.net...
  • Page 72 You can type the character by keyboard (0x20h˜0x7Fh), if you press clear icon, it will clear the all Msg charaters on AP. b. Hex mode Hex mode can define the character from 0x20h to 0xFFh, the range 0x80˜0xFF www.colormetric.net Colormetrics P2500...
  • Page 73 Colormetrics P2500 www.colormetric.net...
  • Page 74: Configuration Utility Of I-Button Reader

    - Follow the wizard to complete the installation. Launching Program Below steps guide you how to load the Utility program. - From Start/Programs, click HIDMSR-20 Utility folder - Click MagStripe Card Reader Configuration Utility to launch the program. www.colormetric.net Colormetrics P2500...
  • Page 75 Colormetrics P2500 www.colormetric.net...
  • Page 76 • Output order : 5 formats could be select at Attach /Remove i-Button ID 0. 0-All 1- CRC.ID 2- ID, FC 3- ID 4-Disabled Update Settings Once complete the settings, click Update to update the settings to connected HID MSR reader. www.colormetric.net Colormetrics P2500...
  • Page 77 To load pre-saved settings, click Open, specify the settings file, and then click OK to load into program. Restore MSR Reader Settings To load restore settings of connected MSR reader, click Restore ES2: End sentinel for track. Colormetrics P2500 www.colormetric.net...
  • Page 78 Below steps guide you how to install the Utility program. • Insert the setup CD. • Run the Colormetrics i-Button Utility.exe setup file that is located in the Software folder of CD. • Follow the wizard to complete the installation.
  • Page 79 Colormetrics P2500 www.colormetric.net...
  • Page 80 Colormetrics P2500...
  • Page 81 2. To execute “IButton_V1.0.exe” for setup communication between software and iButton module. Colormetrics P2500 www.colormetric.net...
  • Page 82 • The utility program will detect the connected reader. If detected, all the input text boxes will be enabled. • If the reader has not been connected to PC yet, please connect the reader and then click Refresh to get connected. Configuration Below is the main window of i-Button Utility program. www.colormetric.net Colormetrics P2500...
  • Page 83 SS + iButton 64- Bit Registration Number + ES • Length : i-Button ID length request from 0~16 • Output order : 4 formats could be select at Attach /Remove i-Button ID. iButton 64- Bit Registration Number: 8-Bit CRC + 48-Bit ID + 8-Bit FC Colormetrics P2500 www.colormetric.net...
  • Page 84 DEMO SETUP&OUTPUT OUTPUT DATA : a!ab00000003bdfa01? b!ab00000003bdfa01? www.colormetric.net Colormetrics P2500...
  • Page 85: Installation And Testing Of Smart Card Reader

    6-7 Installation and Testing of Smart Card Reader 1. Check smart card reader be detected by “Device manager”. 2. Install the SCR driver. Colormetrics P2500 www.colormetric.net...
  • Page 86 3. Run Setup.exe. 4. Click “Yes”. www.colormetric.net Colormetrics P2500...
  • Page 87 5. Restart systems. 6. Check SCR reader in Device Manager. Colormetrics P2500 www.colormetric.net...
  • Page 88 BIOS/UTILITY SETUP 7. Run the testing program – EZ100test. 8. Conferm that SCR can be detected by the testing program, the Start Testing www.colormetric.net Colormetrics P2500...
  • Page 89 9. Follow dialog boxes displayed to remove and insert card. 10. After finishing the testing, the dialog box will show “oK”. Colormetrics P2500 www.colormetric.net...
  • Page 90: Wifi

    6-8 WiFi 1. Install the WiFi driver. 2. Select “I accept the terms of the license agreement” and click “Next” www.colormetric.net Colormetrics P2500...
  • Page 91 3. Select “Install driver and Ralink WLAN Utility” and click “Next” 4. Click “Install” Colormetrics P2500 www.colormetric.net...
  • Page 92 5. Starting install 6. Click “Finish” www.colormetric.net Colormetrics P2500...
  • Page 93 6-9 Pole type VFD VD1220 1. Power on VFD and waiting test page of EEPROM test, Baud rate and Command page. Set up the customer display by „ VFDset.exe” 2. Setup VFDset.exe software. Colormetrics P2500 www.colormetric.net...
  • Page 94 Please then follow the steps as shown in the above figure, the baud rate will show on states page of VFD module (Note: You may check it when power on VFD module), then click “Open COM” button. 4. “Get Setting from VFD” button to get all the settings from Colormetrics and it’ll refresh the “VFDset.exe” software.
  • Page 95 Message characters on AP. b) Hex mode Hex mode can define the character from 0x20h to0xFFh the range 0x80~0XFF which depends on the code page table. Like the first character (0x80) in default code page will show on VFD module. Colormetrics P2500 www.colormetric.net...
  • Page 96 “Download O.K! Please restart!” message popped up. Please restart display for enable new setting. 9. Click “Download setting to VFD” button To save user’s setting in file; for example, below picture to save file name as “GOODLUCK” file set for Welcome Message. www.colormetric.net Colormetrics P2500...
  • Page 97 10. Click “Load’ button After saving, you must restart the utility here. Then load your setting rename-GOODLUCK.vfd. Colormetrics P2500 www.colormetric.net...
  • Page 98: Bios/Utility Setup

    BIOS/UTILITY SETUP 7 BIOS/Utility setup BIOS/Utility setup Press <ESC> key to enter BIOS SETUP UTILITY when system boot up. Please press ESC key tenderly and slowly. www.colormetric.net Colormetrics P2500...
  • Page 99 OS, these items are automatically updated whenever you make changes to the Windows Date and Time Properties utility. WARNING! Setting the wrong values in the sections below may cause the system to malfunction. Make sure that the settings made are compatible with the hardware. Colormetrics P2500 www.colormetric.net...
  • Page 100 7-1 Advanced Use the Advanced menu to configure the system for basic operation through the following sub-menus: www.colormetric.net Colormetrics P2500...
  • Page 101 7-1-1 Boot Configuration Use the Boot Configuration menu to select power-on state for Numlock. Colormetrics P2500 www.colormetric.net...
  • Page 102 7-1-2 Audio Configuration Use the Audio Configuration menu to read Audio configuration information and configure the Audio settings www.colormetric.net Colormetrics P2500...
  • Page 103 7-1-3 Video Configuration Use the Video Configuration menu to read Video configuration information and configure the Video settings Colormetrics P2500 www.colormetric.net...
  • Page 104 7-1-4 SATA Configuration Use the SATA Configuration menu to read SATA configuration information and configure the SATA settings www.colormetric.net Colormetrics P2500...
  • Page 105 7-2 Security Use the Security menu to install or change the password Colormetrics P2500 www.colormetric.net...
  • Page 106 This item allows you to enable or disable power button delay 4s COM Voltage This item allows you to select off, 5V or 12V powered COM LVDS Firmware update This item allows you to enable or disable LVDS Firmware update www.colormetric.net Colormetrics P2500...
  • Page 107 7-4 Boot Use the Boot menu to select type to Dual type, Legacy type or UEFI type. Colormetrics P2500 www.colormetric.net...
  • Page 108 7-5 Exit Use the Save & Exit menu to load default BIOS values, optimal failsafe values and to save configuration changes. www.colormetric.net Colormetrics P2500...
  • Page 109: Lcd Surface Cleaning

    3. What types of cleaners are acceptable? • Water • Vinegar (mixed with water) • Isopropyl Alcohol NOTICE: The following cleaners are unacceptable: • Acetone • Ethyl alcohol • Ethyl acid • Ammonia • Methyl chloride Colormetrics P2500 www.colormetric.net...
  • Page 110 (WEEE). The Directive determines the framework for the return and recycling of used appliances as applicable throughout the European Union. This label is applied to various products to indicate that the product is not to be thrown away, but rather reclaimed upon end of life per this Directive. www.colormetric.net Colormetrics P2500...

Table of Contents