Siemens SIMEAS P 7KG7550 Operating Instructions Manual page 16

Power meter
Table of Contents

Advertisement

Binary outputs
Permissible voltage
Permissible current
Internal resistance
Permissible operating
frequency
Analog outputs
Nominal output current
Output range
Max. load resistance
Accuracy
Relay outputs
Rated voltage
Max. permanent current
Min. permanent current
Rating (resistive)
Max. response time
Max. release time
Overvoltage category
V
to 480 V (L-L)
IN
V
to 600 V (L-L)
IN
Power Supply
Binary outputs, binary inputs
and relay outputs
Via isolated solid-state relay
230 V/AC; 250 V/DC
100 mA continuous
300 mA for 100 ms
50 Ω
10 Hz
(optional, only 7KG7660)
0 to 20 mA DC
0 to 24 mA DC
250 Ω
0.2% (typical); max. 1.1% of the
nominal value
(optional, only 7KG7660)
250 V AC / 150 V DC
5 A
0,1 mA at 100 mV DC
5 A / 250 V AC or 5 A / 30 V DC
10 ms
7 ms
According to IEC 61010 Part1
Cat III
Cat II
Cat II
Cat II
14