Hardware Contact - Advantech LNC M5800 Series Operation Manual

Table of Contents

Advertisement

Milling Machine Series
CNC operations
1.7.5

Hardware contact

Description of the hardware contact function:
Users can use this function to examine the I/O signal status of hardware connected externally to the controller.
Instructions for using hardware contact:
After using the <MAINTE> key on the MDI panel to switch to maintenance group, the 【Hardware contact】 key
can be pressed to access the hardware contacts page.
【Signal input】: examine the status of signal input at point I.
【Signal output】: examine the status of signal output at point O.
【Force close】 : forcibly set the I/O point signal status to close, and then press 【Update now】 after the setting
is completed.
【Force open】 : forcibly set the I/O point signal status to open, and then press 【Update now】 after the setting
is completed.
【Update now】: update signal status.
【Find】: enter the parameter number you wish to find in the input area, then press the 【Find】 key to quickly
search and move the cursor to the position of that number.
86