3.3 Fuser
1. Before you remove the Fuser, you should
remove:
- Top Cover(see page 3-2)
2. Unplug two connectors(Block) from the boards,
then remove four screws.
3. Remove two screws and take the Thermostat
out of the Fuser.
4. Remove two screws and take the Halogen
Lamp out of the Heat Roller.
Heat Roller
Halogen Lamp
Fuser Ass'y
Thermostat
Disassembly and Reassembly
5. Remove one screw and take the Idle Gear out.
Idle Gear
6. Remove four screws and divide the Fuser into
two parts
7. Remove the Thermister from the Fuser Cover.
Fuser Cover
Thermister
Service Manual