3. Connection
Optimal mounting parameters:
1. Minimal length from the ground > 1,5 m,
2. Minimal length from the wall and ceiling > 0,3 m,
3. Minimal length between receivers > 0,2 m.
protective wire
protective wire
(power supply)
(motor)
phaze wire
(power supply)
neutral wire
(power supply)
1st direction
(motor)
power supply:
neutral wire
(motor)
230 V / 50 Hz
2nd direction
(motor)
Installation of the tubular motor should be performed by specialists with 1kV or higher SEP-certified electrician's licence
(SEP - Association of Polish Electrical Engineers) or equal license. Device is designed to operate in places shielded from
unfavourable weather conditions. Motor should be installed in accordance with all provisions of regional law and profe
sional standards. All cables connecting power receiver with electric source should be protected from overload and
short-circuits effects with devices automatically disconnecting power. Device should be powered with a separate source
and protected only with a fast-blow fuse (never slow-blow fuse). Creating electrical system using inadequate fuse may
result in loosing rights under the provisions of warranty. When connecting device to power source with cables with
adequate cross-section should be used. Long-lasting output load capacity table should be the ground for choosing
adequate cables.
4. Programming transmitters
1. Longer than 10 seconds pause between series of button clicks during programming will cause device to switch off from
programming mode without saving any changes.
2. Procedure described below is to be used for programming first and all other transmitters.
3. Receiver can hold in its memory up to 20 different transmitters. Adding more transmitters will remove the first
programmed transmitters.
Switch
Press programming button
power on.
(LED diode start to flash).
Deleting the transmitter
1. Longer than 10 seconds pause between series of button clicks will cause device to switch off without saving any
changes.
2. Performing the procedure removes only one transmitter.
Switch
Press programming button
power on.
(LED diode start to flash).
Press STOP button
Press UP button
(LED diode stops to flash).
on transmitter that
is beeing programmed.
Press STOP button
Press DOWN button
(LED diode stops to flash).
on transmitter that
is beeing deleted.
2
The transmmiter
programmed.
The LED on the receiver will
flash and then turn off.
The transmmiter has
The LED on the receiver will
flash and then turn off.
motor:
230 V / 50 Hz
has been
been deleted.