Operating Hints; Device Overview - Honeywell homexpert Rondostat COMFORT+ HR30 Manual

Electronic radiator controller
Table of Contents

Advertisement

Setting the position of the display
In order to improve the legibility the display of the
radiator controller can be tilted to different positions
(10°, 20°, 30°, 40°).
The angle of 40° can be fixed with the supplied display
element.
1. Lift the display and set it to the desired angle.
2. If desired to fix the angle at 40°, slide the support
bracket between the display and the main body until it
clips into place.

4. Device overview

operating elements and display
11
10
9
8
AUTO
ECO
MANU
1 Heating/Conserve period in hours
2 Current weekday 1 ... 7 (Monday ... Sunday)
3 Temperature display: e.g. current room temperature
or measured temperature, if configured in
Parameter 9
4 Text display with 9 characters
5 Button
OK
: Confirm settings
6 Button PROG: Select the operating modes, set the
time program;
Button pressed long (approx. 10 seconds):
Parameters can be changed;
Programming: Back to next level up
1.
2.
1
2
3
4
5
PROG
OK
6
7
7 Adjustment dial: Change settings
8 Button AUTO/ECO/MANU: Change between
automatic, ECO and manual mode
In programming mode: Terminate (without storing)
9 Battery status
10 Operation lock
11 Symbol for Comfort temperature 1
Comfort temperature 2
Battery display
Battery status
Meaning
Batteries full
Batteries half-full
Batteries have to be replaced soon
Flashing display: Batteries are flat and
have to be replaced

operating hints

operating the radiator controller comfortably
The radiator controller can be removed from the radiator
to facilitate programming.
1. Unlock the radiator controller. To do so, slide the slide
at the radiator controller towards the
2. Pull the radiator controller off the valve baseplate.
Lost your way in the program?
fPress the button AUTO/ECO/MANU
is displayed. The last entry is rejected.
automatic
5. Functionality in automatic mode
Standard time program
In automatic mode the radiator controller automatically
controls the room temperature in accordance with the
stored time program.
- 4 -
,
, Conserve temperature
1.
2.
.

Hide quick links:

Advertisement

Table of Contents
loading