Page 1
INSTALLATION GUIDE ILCO Q90 RFID (Quantum Series) PK3656...
Page 2
Any misuse of this confidential information contained herein may result in legal action by Kaba Ilco Inc. and its parent company. PK365 6_ 07_ 1 4 • IL C O Q9 0 I N ST AL LAT I ON G U I D E...
Page 3
Preparing the door and door frame Prepare the door using the Q90 reader installation template or drill fixture. The door edge prep is a standard, full-mortise prep for a 1-1/4” x 8” front plate (1” x 8” and 1” x 7-3/4” custom front plates are optional). The door surface holes and mortise are customized for the Q90 trim.
Page 4
Preparing the door and door frame (continued) T he mortise plate has an adjustable bevel. Align the mortise front plate with the bevel of the door edge and tighten the two bevel adjustment screws at the top and bottom of the mortise case. Position the mortise case in the door edge with the motor wire routed through the notch (see Fig. 3). Note: Use care to ensure that the wires do not get pinched or pulled as the mortise is inserted into the pocket. Attach the mortise front plate to the door using the two mortise screws (12 x 1-1/4 screws for wood doors, 12-24 x 3/8 screws for metal doors).
Page 5
Installing the lock trim The outside lever trim has two carriage bolts that fit into the diagonal holes in the mortise case. These carriage bolts establish an accurate trim position with respect to the mortise case assembly, allowing the levers and bolt mechanism to operate without binding. The holes machined in the door surfaces should not influence the position of the trim or the card reader assembly. Do not tap or bend the carriage bolts to manipulate the fit of either trim piece during installation. The door prep holes should accommodate the outside lever trim and the card reader assembly. If the carriage bolts or card reader enclosure fit too tightly in the door prep holes, remove the mortise and enlarge the holes to achieve a free fit.
Page 6
Installing the lock trim (continued) C onnect reader ribbon cable, reader power cable, motor cable, and power wire to the PCB. See Fig. 6. Be sure not to crease the ribbon. Watch for the green LED on the card reader to flash once, and for the clutch motor to reset when you connect the battery wire to the PCB. This is an indication that the PCB has reset and the door is locked. Important: The battery wire should be the last connection made to the PCB. 10.
Page 7
Installing the lock trim (continued) 13. Secure the inside trim cover to the inside trim using two M4 x 16mm Torx screws (see Fig. 7). M4 x 16mm Torx Fig. 7 14. P rogram the lock using the FDU and Q90 programmimg module. Test the functioning of the lock as indicated in the following section and in the programming manual before closing the door. When the installation keycard is used, the green and red LEDs will blink together, then the green LED will blink once indicating that the lock’s time and date are not set.
Page 8
Testing Lock Functionality Pass a programming key card over the Q90 RFID reader. The green light will stay illuminated for 30 seconds. This will indicate the lock is ready to be programmed. After programming, present the emergency keycard. The mechanism will unlock. Lock Communication Electronic Function Description Green LED illuminates for Time and date not set, use the Q90 RFID LPI probe to reset. This will be done during programming or using the FDU to reset the time 30 seconds Dead bolt is thrown or switch cam is not properly aligned Red LED flashes 12 times Keycard not allowed OR keycard cancelled by new keycard No light...
Door Unit Inspection Criteria Appearance • Finish is free of blemishes or scratches that would distract from lock appearance • Lock body and under plate (if used) are mounted straight on the door • Door scalp is mounted straight and flush with the door edge • Jamb strike is mounted straight and is flush with the jamb face • Correction of minor blemishes on the door jamb are the responsibility of the property’s maintenance department Lock Function • Knob or lever rotates and moves freely • Lever is horizontal to floor when at rest position • Dead bolt extends fully and retracts without binding (door open) • Lock latch and dead bolt engage jamb strike plate freely • Anti-pick latch when depressed (door open) • Anti-pick latch is depressed when contact is made with the strike plate (door closed) Electronics/Keycards • An invalid keycard will be ignored by the lock. No LED feedback. • The green LED flashes 8 times or for 4 seconds when a valid keycard is presented • The LED continues to flash green when the lever is operated • The LED flashes green 8 times when a guest card is presented while the deadbolt is projected • The LED flashes green 8 times when a staff card is presented while the deadbolt is projected • The red LED flashes once when a valid guest card is presented while privacy is enabled. Access is denied • The red LED flashes 8 times when a staff card is presented while privacy is enabled. Access is granted.
Page 10
Online Consumable Orders: www.ilcostore.com To access all of our easy steps, please visit our Support Website: www.ilcosupport.com Kaba Ilco Inc. reserves the right to modify the characteristics and features of all products in this publication. @Kaba Ilco Inc. 2014 all rights reserved...
Need help?