Current Consumption - Quectel M12 Hardware Design

Cellular engine
Table of Contents

Advertisement

M12 Hardware Design
Parameter Description
Peak supply
current
(during
transmission
slot)
1)
Power control level PCL 5
2)
Power control level PCL 0

5.4. Current consumption

The values for current consumption are shown in Table 31.
Table 31: The module current consumption
Condition
Voice Call
GSM900
DCS1800
GPRS Data
DATA mode, GPRS ( 1 Rx,1 Tx ) CLASS 12
EGSM 900
DCS 1800
DATA mode, GPRS ( 3 Rx, 2 Tx ) CLASS 12
EGSM 900
DCS 1800
DATA mode, GPRS ( 2 Rx, 3 Tx ) CLASS 12
EGSM 900
M12_Hardware_Design_V3.3
Conditions
2)
DCS1800
Maximum power control level
on GSM900.
Current Consumption
@power level #5 <270mA,Typical 220mA
@power level #12,Typical 99mA
@power level #19,Typical 73mA
@power level #0 <230mA,Typical 197mA
@power level #7,Typical 94mA
@power level #15,Typical 70mA
@power level #5 <350mA,Typical 193mA
@power level #12,Typical 84mA
@power level #19,Typical 63mA
@power level #0 <300mA,Typical 185mA
@power level #7,Typical 82mA
@power level #15,Typical 60mA
@power level #5 <550mA,Typical 373mA
@power level #12,Typical 150mA
@power level #19,Typical 103mA
@power level #0 <450mA,Typical 340mA
@power level #7,Typical 145mA
@power level #15,Typical 98mA
@power level #5 <600mA,Typical 515mA
@power level #12,Typical 178mA
Min Typ
Max
477
1.6
1.8
Unit
mA
A
- 66 -