Operator Diagnostic Test 01; Functional Fault Recovery Procedures - Honeywell DPS 6 PLUS Operation

Mtu9921/9922 gcr/pe magnetic tape unit
Table of Contents

Advertisement

(/
(
Table
4-1.
Functional Fault Recovery Procedures
Fault Code
10
11
12
13
14
15
16
17
18
20 through 29
30 through 99
Cause
Operator door open
Tape not threaded
Hub not latched
Tape incorrectly
threaded
Bar marker fault
RESET button aborted
LOADIUNLOAD
Tape not write enabled
Ear marker fault
Tape already loaded
TapelUnit fault
Unit fault
Corrective Procedures
Ensure that front door is securely closed.
Thread tape.
Check that the supply reel hub is latched, the Bar
marker is located correctly, or correct the tension
fault which occurred during the load operation.
If a tension fault occurred, the tape may be wound
too tightly and not stablized. Thread the tape (do
not load) and press the LOAD button and then the
TEST button
to
reset the tension ofthe tape.
Refer to Figure 3-3 to ensure that tape is threaded
correctly.
Check that Bar marker is positioned correctly (see
Figure 4-4). If fault condition still occurs, replace
with tape of known good quality.
RESET button was pressed inadvertently by oper-
ator. Reinitiate test.
Check for presence of a write-enable ring in rear of
supply reel. Install ring if one is not present.
Check for presence of Ear marker. Iffault condi-
tion still occurs, replace with tape
of
known good
quality.
Tape was loaded when the test was initiated.
Thread tape, but do not press LOAD button.
Execute appropriate system diagnostic test and
operator diagnostic Thst 01.
Execute the appropriate system diagnostic test and
operator diagnostic Thst 01.
Operator Diagnostic Test 01
Operator diagnostic test 01 must be run when specified in Table 4-1. Upon com-
pletion of the test, refer to Table 4-2 for corrective procedures.
When no errors are detected during diagnostic test 01, the test runs for approxi-
mately 13 minutes, if a 2400-ft, 10.5-inch tape reel is used. Test time varies with
other size tape reels. The test is interrupted and a numeric fault code appears on
the two-digit display when a fault is detected.
Operator Maintenance
HD52-OO

Advertisement

Table of Contents
loading