Before performing the following maintenance, open the dust cover door and make
r-'\
sure the supply reel and head assembly dust covers (Figure 4-1) are removed.
\...,_,,/
CAUTION
Set the power supply circuit breaker to the OFF position (0 side pressed
down).
Figure
4-1.
Head Assembly Dust Covers
Figure 4-2 illustrates the tape deck components that must be cleaned as follows:
• Magnetic head - Clean the magnetic head recording surface using a lint-free
cloth moistened with Honeywell All Purpose Cleaner. Make sure
to
wipe the
recording surface in the same direction that the tape. moves across the head
(from top to bottom) applying sufficient pressure to remove all foreign matter
from the head. Repeat as necessary to insure it is clean.
• Tape cleaner - Use a foam-tipped swab moistened with Honeywell All Purpose
Cleaner to remove dirt and oxide deposits from the tape cleaner blades.
• EOTIBOT sensor - Use a foam-tipped swab moistened with Honeywell All
Purpose Cleaner to remove dirt and oxide deposits from the EOTIBOT sensor.
Operator Maintenance
4-2
1/87
HD52-00A