Aqua Lung MISTRAL SECOND STAGE Technical Maintenance Manual page 15

Table of Contents

Advertisement

Mistral Second Stage Technical Maintenance Manual
TEST
Leak Test
Opening Effort
Flow Effort
Table 4: Torque Specifi cations
PART #
DESCRIPTION / KEY ITEM #
104106
Inlet fi tting (19)
Table 5: Checking Specifi cations
CONDITION
Inlet 2500 - 3000 (± 100 psig)
Inlet 2500 - 3000 (± 100 psig)
MP 135 ± 5 psi
MP 135 ± 5 psi at 15 SCFM
TORQUE
85 in/lbs
SPECIFICATIONS
No leaks allowed
+ 1.0 – 1.7 in. H ² O
+ 6 in. /H ² O (Maximum)
15