Near Loops; Far Loops; Configuration Screen - Verilink PRISM 4051 Manual

Dds csu/dsu
Table of Contents

Advertisement

30
C
4: T
HAPTER
ERMINAL
Configuration
Screen
O
PERATION
exceeded. Status indications are described in the NET and DTE Status fields.
Status indications are described in Table 4-4.
Table 4-4
Status Indications
Status
Description
-------
No status is available
OK
No errors are currently detected.
LOS
A loss of signal condition exists.
OOF
An out of frame condition exists or OOF codes are received.
OOS
Out of Service codes are received.
DTR
DTR from the DTE device is false.

Near Loops

Displays the loop status of the near element.

Far Loops

Displays the loop status of the far element.
The Configuration screens allow viewing and setting configuration parameters for
the network elements. Figure 4-10 shows the screens and where information about
them is located in the manual.
DDS Network
DTE Port
Parameters
Parameters
page 31
page 32
igure 4-10
Configuration Menu
To send a new configuration to the unit, press Enter on one of the fields or exit the
screen. The underlined values are the factory default parameters.
Changing any of the configuration settings of an active 4051 causes a brief
synchronization loss.
Configuration Menu
Alarm
Management
Parameters
Parameters
page 33
page 34
Summary