Maintenance Screen

O
PERATION
The Element Maintenance screen (Figure 4-4) allows performing loop tests and/or
BERT functions on the DDS circuit. This screen also allows activating and
clearing loops and the BERT tester. BERT is performed by using on-board test
facilities. No other test equipment is needed. Some of these tests may also be
activated by the front panel switch as described in chapter Operation.

Clear Tests

Pressing Enter on this field clears all local tests and any line loops that have been
initiated.

Clear Alarms

Pressing Enter on this field causes all near end alarms to be cleared.

Loop

The type of loop is chosen by toggling the spacebar and is executed by pressing
Enter. Options include LOCAL, V.54, and FAR V.54. Local and V.54 generate
near-end loops. Far V.54 generates a V.54 loop at the far end.
A FAR V.54 loop started from the front panel switch cannot be unlooped from the
Maintenance screen. It must be unlooped from the front panel switch.

Unloop

Pressing Enter takes down the specified loop from the selected port. The type of
loop is chosen by toggling the spacebar and is executed by pressing Enter. Options
include LOCAL, V.54, and FAR V.54.
4051 DDS 255.255/1.02
------------------------------- ELEMENT MAINTENANCE ----------------------------
(CLEAR TESTS)
(CLEAR ALARMS)
Loop:
[LOCAL
Unloop:
[LOCAL
Loop More: [BIDIRECTIONAL
(ACTIVATE REMOTE ACCESS)
NET Status: LOS OOF
DTE Status: OK
Near Loops:
Far Loops:
------------------------------------ Messages ----------------------------------
Figure 4- 4
Element Maintenance Screen
P R I S M
4 0 5 1
(Unit Address: 1)
]
]
]
Date: 08/23/96
Time: 09:14:26
BERT:
[DDS NETWORK]
Test Length:
[Cont. ]
Pattern Sync:
NO TEST
Elapsed Time:
00:00:00
Bit Errors:
0
Errored Seconds:
0
% EFS:
100
(START TEST)
(RESET ERRORS)

Advertisement

Table of Contents
loading

Table of Contents