|nsta||er's
Guide
CHECKOUT
PROCEDURE
After
installation
has
been
completed,
it is recommended
that
the
entire
system
be checked
against
the following
list:
1. Refrigerant
Line, Leak checked
..................................
[
2. Suction
Lines and Fittings
properly
insulated
........... [
3. Have all Refi'igerant
Lines been secured
and
isolated
properly?
........................................................
[
4. Have passages
through
masonry
been sealed?
If mortar
is used, prevent
mortar
from coming
into direct contact with copper tubing
........................
[
5. Verify tightness
of all electrical
connects
...................
[
6. Observe outdoor
fhn during on cycle for clearance
and smooth operation
..................................................
[
7. Indoor coil drain line drains
freely. Pour water
into drain
pan ..............................................................
[
]
8. Supply registers
and return
_'illes
open and
]
unobstructed
................................................................
[
]
9. Return
air filter installed
............................................
[
]
]
10. Thermostat
thermometer
is accurate.
Check
against
a reliable
thermometer.
Adjust
per
instructions
with thermostat
......................................
[
]
]
11. Is correct speed tap being used?
]
(Indoor blower motor) ..................................................
[
]
12. Operate
complete
system
in each mode to
insure
safe operation
...................................................
[
]
CHECKOUT
PROCEDURE
WiTH MAiN P(
Step
No.
TO CHECK
1
Sump Heat
2
IndoorFan Operation
3
CoolingOperation
4
CheckingPerformance
& Charge
5
Heating@
6
Off
iNDOORTHERMOSTAT
SWITCHSETTING
@
@
Fan Switch
Cool
Heat
Auto
On
X
X
)WER DISCONNECTS
CLOSED (ON)
COMPONENT OPERATION
indoor
Outdoor
Blower
Fan
Runs
Runs
Compressor
@ Comp.
Furnace
Runs
Sump
Heat
Heater
Comes On
X
X
X
X
X
X
X
X
X
X
x
Ix
I
x
I
x
x
USE CHARTS ATTACHED TO O.D. UNIT
Informowner on howto operatesystem andwhat to expectof it. At the sametime deliverOwner'sUseand Care Booklet.
@ Also set thermostat dial to call for cooling or heating as necessary.
@
Check only necessary if heating unit is used for indoor section and wiring has been disturbed during installation of cooling equipment,
@ When applicable.
ARI Standard
210/240 UAC
05/08
1r]MN£