Download Print this page

Bosch Professional GWS 18-125 L Original Instructions Manual page 14

Hide thumbs Also See for Professional GWS 18-125 L:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
OBJ_BUCH-3473-001.book Page 14 Thursday, December 14, 2017 10:33 AM
14 | English
When cutting profiles and square bar, it is best to start at the
smallest cross section.
Cutting Stone
 Provide for sufficient dust extraction when cutting
stone.
 Wear a dust respirator.
 The machine may be used only for dry cutting/grinding.
For cutting stone, it is best to use a diamond cutting disc.
When using the cutting guide with dust extraction protection
guard 21, the vacuum cleaner must be approved for vacuum-
ing masonry dust. Suitable vacuum cleaners are available
from Bosch.
For cutting especially hard material, e. g., concrete with high
pebble content, the diamond cutting disc can overheat and
become damaged as a result. This is clearly indicated by cir-
cular sparking, rotating with the diamond cutting disc.
In this case, interrupt the cutting process and allow the dia-
mond cutting disc to cool by running the machine for a short
time at maximum speed with no load.
Noticeably decreasing work progress and circular sparking
are indications of a diamond cutting disc that has become
dull. Briefly cutting into abrasive material (e. g. lime-sand
brick) can resharpen the disc again.
Information on Structures
Slots in structural walls are subject to the Standard DIN 1053
Part 1, or country-specific regulations.
These regulations are to be observed under all circumstanc-
es. Before beginning work, consult the responsible structural
engineer, architect or the construction supervisor.
1 609 92A 3ZY | (14.12.17)
Maintenance and Service
The machine must al-
ways work in an up-
grinding motion. Other-
Maintenance and Cleaning
wise, the danger exists
 Before any work on the machine itself, pull the mains
of it being pushed un-
plug.
controlled out of the
 For safe and proper working, always keep the machine
cut.
and ventilation slots clean.
 In extreme conditions, always use dust extraction as
far as possible. Blow out ventilation slots frequently
and install a portable residual current device (PRCD).
When working metals, conductive dust can settle in the in-
terior of the power tool. The total insulation of the power
tool can be impaired.
If the replacement of the supply cord is necessary, this has to
be done by Bosch or an authorized Bosch service agent in or-
der to avoid a safety hazard.
Please store and handle the accessory(-ies) carefully.
After-sales Service and Application Service
Our after-sales service responds to your questions concern-
ing maintenance and repair of your product as well as spare
parts. Exploded views and information on spare parts can al-
so be found under:
www.bosch-pt.com
Bosch's application service team will gladly answer questions
concerning our products and their accessories.
Switch on the machine
In all correspondence and spare parts orders, please always
and place the front part
include the 10-digit article number given on the nameplate of
of the cutting guide on
the product.
the workpiece. Slide the
Cambodia
machine with moderate
Robert Bosch (Cambodia) Co., Ltd
feed, adapted to the ma-
Unit 8BC, GT Tower, 08th Floor, Street 169,
terial to be worked.
Czechoslovakia Blvd, Sangkat Veal Vong
Khan 7 Makara, Phnom Penh
VAT TIN: 100 169 511
Tel.: +855 23 900 685
Tel.: +855 23 900 660
www.bosch.com.kh
People's Republic of China
China Mainland
Bosch Power Tools (China) Co., Ltd.
567, Bin Kang Road
Bin Jiang District 310052
Hangzhou, P.R.China
Tel.: 4008268484
Fax: (0571) 87774502
E-Mail: contact.ptcn@cn.bosch.com
www.bosch-pt.com.cn
HK and Macau Special Administrative Regions
Robert Bosch Co. Ltd.
21st Floor, 625 King's Road
North Point, Hong Kong
Customer Service Hotline: +852 2101 0235
Fax: +852 2590 9762
E-Mail: info@hk.bosch.com
www.bosch-pt.com.hk
Bosch Power Tools

Advertisement

loading

This manual is also suitable for:

Professional gws 18-125 plProfessional gws 18-125 slProfessional gws 18-125 splProfessional gws 18-125 l inoxProfessional gws 18-125 pl inoxProfessional gws 18-150 l ... Show all