5.3
12
To cable a single-node A10, complete the following steps, using the
diagram for reference.
5.3.1 Cable the N3300 port 0a to the first expansion unit module A
ESH2/ESH4 or AT-FCX In port.
5.3.2 Cable the N3300 port 0b to the first expansion unit module B
ESH2/ESH4 or AT-FCX In port.
5.3.3 For any additional expansion units in a loop, connect the
module A Out port to the next expansion unit's module A In port.
Repeat for module B.
Note:
Both the ESH2/ESH4 and the AT-FCX modules are self-
terminating.The ESH2/ESH4 does not have a terminate switch.
5.3.5 Go to Step 6 on page 16.
EXN
EXN
5.3.1
N3300
Notes:
1.
Ill ustrations in this document show storage system connections to EXN2000/EXN4000
expansion units. On EXN1000 expansion units, the positions of the In and Out ports
are reversed from those of the EXN2000/EXN4000.
2. This illustration shows only the first two expansion units in a loop. The number of
expansion units per loop might be different for your configuration.
A
OUT
PSU
IN
OUT
B
A
OUT
PSU
B
IN
OUT
PSU
10101
0a
0b
IN
PSU
IN
PSU
5.3.2
PSU
e0a e0b