Troubleshooting - Dometic ECOLINE RH430LD Installation And Operating Manual

Minibar
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11
RH4xxLD, RH4xxLG
➤ Use a soft cloth, lukewarm water and a mild detergent to clean the inside of the
cooling device.
➤ Wash out the cooling device using clean water and dry thoroughly.
➤ At annual intervals, remove dust from the cooling aggregate at the back of the
cooling device using a brush or a soft cloth.
8.1
Changing the device light
!
WARNING!
Always disconnect the device from the power supply before you
change the device light.
The device uses a LED board as illuminant. A new LED board can be obtained from
Dometic.
➤ Change the LED light as follows: fig. s, page 10
9

Troubleshooting

Problem
Device is not cooling
(the cooling unit at
the back of the
device is cold).
Device is not cooling
(the cooling unit at
the back of the
device is warm).
EN
Possible cause
The device plug is not
plugged in.
No voltage present in the
AC voltage socket.
The device is in its defrost-
ing phase.
The electronics or the sen-
sor is defective.
The heating element is
defective.
The device is not level.
The device was only
switched on a short while
ago.
The cooling unit is
defective.
Troubleshooting
Suggested remedy
Plug the device plug in.
Check fuse or try using another plug
socket.
Check again if the device is cooling
after 2 hours as the defrosting phase
lasts 2 hours.
This can only be repaired by an author-
ised customer services unit.
This can only be repaired by an
authorised repair centre.
Level the device using a spirit level.
Let the device run for 5 to 6 hours.
This can only be repaired by an
authorised repair centre.
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents