Richard W Schneider
February 14, 2025
the timer stays in over ride mode and it does not keep the time.
1 comments:
Mr. Anderson
February 14, 2025
The Paragon EC7000 Series timer stays in override mode and does not keep time because input power only enables the control to keep time, store programmed information, and carry out instructions, but it does not power the load. To make circuits function properly, power must be provided to the contacts. If the timer is not updating itself, it may be due to a lack of proper power supply to the unit or incorrect programming.
Page 1
Replacement timer http://waterheatertimer.org/Intermatic-ET-series-timers-and-manuals.html#ET1700 EC7000, EC7004 and EC7005 Single Channel Electronic Time Controls GENERAL INSTRUCTIONS S P E C I F I C C A PA B I L I T I E S • 16 Setpoints - A setpoint defines the type of event (ON, OFF or duration) as well as the time and day(s) on which the event will occur.
Page 2
I N T RO D U C T I O N The EC7000, EC7004 and EC7005 are single-channel, electronic time control that provides simple, inexpensive control of lighting, heating, ventilation, air-conditioning, security systems, motors, pumps, fans or any load with a time-of-day schedule. The control may be utilized as a 24-hour or 7-day control.
EC7005 Please refer to inner door instructions on unit or contact factory NOTE: Paragon solid state controls utilize dry contacts, input power enables the control to keep time, store programmed infor- mation and carry out instructions but input power does not power the load.
Page 4
WIRING Terminals can accommodate 10-16 AWG wire. POWER OUTAGE CARRY-OVER The program and time-of-day are maintained during a power out- age for a minimum of 4 days. A built-in special capacitor elimi- nates the inconvenience of battery replacement. ENVIRONMENTAL EC7000 & EC7004 should be mounted indoors in an environ- ment that is free from excessive contaminants such as oil, mois- ture and dirt.
K E Y PA D D E S C R I P T I O N EC7000, EC7004 and EC7005 RUN- Returns timer to the RUN mode. The timer will only control the load when in the RUN mode. MODE- Advances from one programming mode to the next.
U N D E R S TA N D IN G S E T P O IN T S Before you begin programming, make sure you understand set- points and durations. A setpoint defines the type of event - ON, OFF or momentary, as well as the time of the event and the day(s) on which the event will occur.
Page 7
P RO G R A M M I N G I N S T RU C T I O N S These timers initially power up in the Clock Format Select Mode. This mode is only accessible once. If the clock format needs to be changed, the timer will have to be reset.
Page 8
SETPOINT PROGRAMMING mode (Refer to Understanding Setpoints and your worksheet.) STEP DESCRIPTION MODE Advances from the SET TIME mode to the SETPOINT PROGRAMMING mode. The timer displays “1” at bot- tom of display and “_ _:_ _”. The “1” indicates that the first of 16 setpoints is being programmed.
Page 9
TO REVIEW SETPOINTS STEP DESCRIPTION MODE Advances from RUN mode to SET TIME mode. (TOD displays.) MODE Advances from SET TIME mode to SETPOINT PROGRAMMING mode. The control will display the first set- point (1 displays at bottom.) To modi- fy the setpoint, go to step 2 of the SETPOINT PROGRAMMING mode instructions.
Press the ENTER key and override the load until the next scheduled setpoint. Maple Chase Company 2820 Thatcher Road Downers Grove, Illinois 60515 Made in Mexico Customer Service Paragon Electric Canada, Ltd. 800-951-5526 5875 Kennedy Road Mississauga, Ontario L4Z 2G3 Technical Support 800-732-8400 From outside North America...
Need help?
Do you have a question about the EC7000 Series and is the answer not in the manual?
Questions and answers
the timer stays in over ride mode and it does not keep the time.
The Paragon EC7000 Series timer stays in override mode and does not keep time because input power only enables the control to keep time, store programmed information, and carry out instructions, but it does not power the load. To make circuits function properly, power must be provided to the contacts. If the timer is not updating itself, it may be due to a lack of proper power supply to the unit or incorrect programming.