Download Print this page

Haier HSU-12LNA/022L(W) Operational Manual page 14

Split type on-off room air conditioner

Advertisement

Operation
Emergency operation and test operation
Emergency operation:
Carry out this operation only when the remote controller
is defective or lost.
When the emergency operation switch is pressed, a "Pi"
sound starts once, which means the start of this operation.
In this operation, it is not possible to change the settings
of temperature and air flow speed, it is also impossible to
do and operation by the timer.
Follow the requirements below.
Room
Designated
Air flow
Timer
Temperature
Temperature
speed
mode
O
O
More then 23 C
26 C
CONTINUOUS
AUTO
Less then 23 C
O
O
CONTINUOUS
AUTO
23 C
If an air conditioner is a model for both cooling and heating.
Cooling when the room temperature at the start of operation is above 23 C.
Heating when the room temperature at the start of operation is less 23 C.
Room
Designated
Air flow
Timer
Temperature
Temperature
mode
speed
More then 23 C
O
26 C
O
CONTINUOUS
AUTO
O
Less then 23 C
23 C
O
CONTINUOUS
AUTO
21
Operation
mode
COOL
HEAT
O
O
Operation
mode
COOL
HEAT
Operation
Test operation:
CUse this switch in the test operation when the room
temperature is less 16 C, do not use it in the normal
operation.
Continue to press the test operation switch for more
then 5 seconds. After your hear the "Pi" sound twice,
release your finger from the switch, the cooling operation
switch with the air flow speed setting "Hi".
Removal of the restriction of emergence or test operation:
Press once more the emergency operation switch, or manipulate through the
remote controller, a "Pi" sound causes the restriction of emergency or test operation
to be removed. When the remote controller is manipulate for the removal, then the
selected operation by the remote controller.