Installation Manual of Room Air Conditioner

1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)

Accessory parts

No.
Accessory parts
1
Remote controller
2
R-03 dry battery
3
Mounting plate
4
Drain hose
5
Steel nail, cement
6
4X25
Plastic cap
Screw
7
Drain-elbow
Cover
8
Cushion
9
10
Pipe supporting plate
11
Connecting cable
Note:Cooling only units don't have Drain-elbow
No.0010518787
Necessary Tools for Installation
5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife
Drawing for the installation of indoor and outdoor units
Number
of
articles
1
Optional parts for piping
Mark
Parts name
2
A
Non-adhesive tape
Adhesive tape
B
1
C
Saddle(L.S) with screws
Connecting electric cable
D
for indoor and outdoor
1
Drain hose
E
F
Heating insulating material
4X50
6
Piping hole cover
G
4
1
Arrangement of piping directions
1
Left
4
1
1
Read this manual before installation
Explain sufficiently the operating means to the user
according to this manual.
Rear left
Rear
right
Right
Below
The marks from
A
to
The distance between the indoor unit and the floor should be
more than 2m.
9.Nipper
10.Gas leakage detector or
soap-and-water solution
11.Measuring tape
Attention must be paid to
the rising up of drain hose
in the figure are the parts numbers.
G
12.Reamer
A
C
D
E

Advertisement

loading

Summary of Contents for Haier HSU-12LEK13-M

  • Page 1: Installation Manual Of Room Air Conditioner

    Cushion Right Below Pipe supporting plate Connecting cable Note:Cooling only units don't have Drain-elbow The marks from in the figure are the parts numbers. The distance between the indoor unit and the floor should be more than 2m. No.0010518787...
  • Page 2 2. Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail.
  • Page 3: Connecting The Indoor/Outdoor Electric Cable

    1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW).
  • Page 4: Connection Of Pipes

    Outdoor unit 1.Connection of pipes To bend a pipe, give the roundness as large as possible not to crush the pipe Connecting the pipe of gas side first makes working easier. The max vertical distance between the indoor unit and the outdoor unit is 5 m.